Copyright© 2014 Data Sciences International
DSI is a pioneering biomedical research company focused on preclinical
systems physiology and pharmacology. The recognized global leader in
physiologic monitoring, DSI offers telemetry, instrumentation, software
and services that facilitate accelerated, well-informed drug therapy and
development decisions.
DSI serves many industries including: Pharmaceuticals, Academia,
Contract Research Organizations, Biological and Chemical defense, the
Medical Device Industry, Government and Biotechnology companies. We
offer solutions that are tailored specifically to meet the unique research
needs of our customers.
Headquarters and North American Sales:
1-800-262-9687 (U.S.)
1-651-481-7400 (International)
sales@datasci.com
datasci.com
European Sales:
Tel: 31-13-5479356
europe-sales@datasci.com
Asia Pacific Sales:
Tel: 86-21-50793177
DSI-shanghai-Office@datasci.com
Better Data. Better Science.
Better Data. Better Science.
About Data Sciences International
Ponemah
Analysis Modules
Start Studies Quickly with Help from
DSI Scientific Services
DSI can help you streamline your studies by providing
expertise you can trust. With our services, we can help
you meet your software validation GLP requirements,
achieve greater implanted telemetry success and
summarize data for confidence in your results.
Data Services
DSI will assist you with creating high quality, useable
reports that summarize your experimental data. The
reduction in time spent on data analysis and reporting
processes will provide you with more time to evaluate
the experimental results and plan your next logical
experiment.
Analysis expertise include hemodynamics, seizure
detection, sleep scoring and ECG evaluation
Comprehensive, useable results
Customized report package
Validation Services
Our experienced team offers a customized program
to help save time and reduce costs associated with
software systems validation.
Customized Validation Solutions Package (VSP) with
test scripts
Industry experienced GLP validation specialists
Contact us today for your free services consultation at
ScientificServices@datasci.com
Ponemah Analysis Modules
Trusted by researchers worldwide to discover
new insights into their research applications.
Confidence
Obtain accurate, consistent results via validated
algorithms developed from scientific and peer-
reviewed journals
Verify analysis accuracy with real-time visual feedback
Operate with full compliance within GLP environments
with the Ponemah Data Security Option (DSO)
Speed
Efficiently refine results by re-analyzing data
segments or manually editing mark placement
Automatically detect noise and eliminate it
from results
On-demand switching between time-based averages
or beat-to-beat data, which automatically export to
Microsoft Excel
®
or Access
®
Versatility
Easily configure modules to analyze various signal
types from any species
Instantly switch between time-based average or
beat-to-beat data
Solutions for all applications, including implantable
telemetry, jacketed telemetry and traditional
hardwired solutions
Copyright© 2014 Data Sciences International
DSI is a pioneering biomedical research company focused on preclinical
systems physiology and pharmacology. The recognized global leader in
physiologic monitoring, DSI offers telemetry, instrumentation, software
and services that facilitate accelerated, well-informed drug therapy and
development decisions.
DSI serves many industries including: Pharmaceuticals, Academia,
Contract Research Organizations, Biological and Chemical defense, the
Medical Device Industry, Government and Biotechnology companies. We
offer solutions that are tailored specifically to meet the unique research
needs of our customers.
Headquarters and North American Sales:
1-800-262-9687 (U.S.)
1-651-481-7400 (International)
sales@datasci.com
datasci.com
European Sales:
Tel: 31-13-5479356
europe-sales@datasci.com
Asia Pacific Sales:
Tel: 86-21-50793177
DSI-shanghai-Office@datasci.com
Better Data. Better Science.
Better Data. Better Science.
About Data Sciences International
Ponemah
Analysis Modules
Start Studies Quickly with Help from
DSI Scientific Services
DSI can help you streamline your studies by providing
expertise you can trust. With our services, we can help
you meet your software validation GLP requirements,
achieve greater implanted telemetry success and
summarize data for confidence in your results.
Data Services
DSI will assist you with creating high quality, useable
reports that summarize your experimental data. The
reduction in time spent on data analysis and reporting
processes will provide you with more time to evaluate
the experimental results and plan your next logical
experiment.
Analysis expertise include hemodynamics, seizure
detection, sleep scoring and ECG evaluation
Comprehensive, useable results
Customized report package
Validation Services
Our experienced team offers a customized program
to help save time and reduce costs associated with
software systems validation.
Customized Validation Solutions Package (VSP) with
test scripts
Industry experienced GLP validation specialists
Contact us today for your free services consultation at
ScientificServices@datasci.com
Ponemah Analysis Modules
Trusted by researchers worldwide to discover
new insights into their research applications.
Confidence
Obtain accurate, consistent results via validated
algorithms developed from scientific and peer-
reviewed journals
Verify analysis accuracy with real-time visual feedback
Operate with full compliance within GLP environments
with the Ponemah Data Security Option (DSO)
Speed
Efficiently refine results by re-analyzing data
segments or manually editing mark placement
Automatically detect noise and eliminate it
from results
On-demand switching between time-based averages
or beat-to-beat data, which automatically export to
Microsoft Excel
®
or Access
®
Versatility
Easily configure modules to analyze various signal
types from any species
Instantly switch between time-based average or
beat-to-beat data
Solutions for all applications, including implantable
telemetry, jacketed telemetry and traditional
hardwired solutions
ECG Pattern Recognition Option (ECG PRO)
Greatly reduce processing time using ECG PROs
template-based analysis as it allows the selection
of a template cardiac cycle for precise comparison
to other cycles in the dataset.
Save time by only attempting to match unmatched
cycles or within specific regions
Automatically adjust the ECG waveform’s cycle
marks based on the template(s)
Systemic Blood Flow (SBF)
Analyzes systemic blood flow from the circulatory
system and eliminates drift resulting from certain types
of flow meters.
• Mean • Flow Maximum • Flow Minimum • Cardiac Output
• Stroke Volume • +dQ • Iso Flow • Total Peripheral Resistance
• Non Pulsatile Mean
PV Loop
Permits the display and analysis of LVP cycles
plotted against cardiac volume cycles.
Characterization of End Systolic Pressure Volume Relationship,
End Diastolic Pressure Volume Relationship and Pre-Recruitable
Stroke Work
Raw Electrical Mean
Analyzes any type of input signal that has no specific
analysis module. This module comes with the Ponemah
application.
• Mean • Maximum • Minimum • Period • Beats per Minute
• Area • Total Activity • Non Pulsatile Mean
Pulmonary Volume (PVO)
Analyzes pulmonary volume signals to derive
respiratory endpoints obtained from respiratory
impedance transmitters (D70-PCTR).
• Peak Inspiratory Flow • Peak Expiratory Flow • Tidal Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Apnea Time • Penh • Relaxation Time
• Tidal Volume (Expiration) • Inspiratory/Expiratory Flow 50%
• Accumulated Volume • Volume Baseline • Volume Fluctuation
• Flow Fluctuation • Median Tidal Volume • Median Tidal Volume
E
xpired • Tidal Volume Throughout • Tidal Volume Expired
Throughout • PZr Ratio
Pulmonary Air Flow and Airway Resistance (PAF)
Analyzes any pulmonary signal derived from a
plethysmography chamber, pneumotach or Jacketed
External Telemetry (JET™) Respiratory impedance bands.
• Peak Inspiratory Flow • Peak Expiratory Flow • Title Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Apnea Time • Specific Airway Resistance
• Phase Shift • Delay Time • Penh • Relaxation Time • Tidal Volume
(
Expiration) • Accumulated Volume • Inspiratory/Expiratory Flow
50% • Ratio EF/IF 50% • Apneic Interval
Unrestrained Plethysmography (URP)
Analyzes signals obtained from unrestrained whole
body plethysmography chambers. Includes the ability to
compensate for environmental conditions to calculate
adjusted volumes.
• Peak Inspiratory Flow • Peak Expiratory Flow • Tidal Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Pause • Penh • TVadj • MVadj • Apnea Time
• Apnea Count • Inspiratory/Expiratory Flow 50% • Ratio EF/IF 50%
• A
pneic Interval
Pulmonary Compliance & Resistance (PCR/PCRP)
Analyzes pulmonary signals from either a
plethysmographic chamber or a pneumotachometer,
along with a pressure, in anesthetized or conscious
animal models.
• Peak Inspiratory Flow • Peak Expiratory Flow • Tidal Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Apnea Time • Resistance • Compliance
• Conductance • Multiple Resistances at Specified Points • Average
C
ompliance • Average Resistance • Pressures at Start of Inspiration/
Expiration • Flow and Pressure at Isovolumetric Points • Penh
• Relaxation Time • Work and Power of Breathing Calculations • Tidal
V
olume (Expiration) • Accumulated Volume • Inspiratory/Expiratory
Flow 50%
Diaphragmatic EMG (dEMG)
Analyzes diaphragmatic EMG signals to provide
respiratory endpoints.
• Respiration Rate • Tidal Volume* • Minute Ventilation*
• Inspiration Time • Expiration Time • Total Time
*
Tidal Volume and Minute Ventilation are only partial
representations as diaphragmatic activity is only a partial
representation of the respiratory mechanics.
Electromyogram (EMG)
Analyzes the electrical activity of muscle tissue.
• Integral • Peak
Action Potential (MAP)
Analyzes a host of action potentials with focus on
key regions such as plateau, recovery time and
upstroke velocity.
• Maximum • EDV • Minimum • Plateau • Amp • Rate • +dV
• -dV • Recovery 1 • xR1 • Recovery 2 • xR2 • Recovery 3 • xR3
• %Max • Time • Count • RiseT
Electroencephalogram (NeuroScore™)
DSI offers NeuroScore CNS analysis software for
sleep and seizure detection. NeuroScore is fully
compatible with the Ponemah system and can analyze
data collected by implantable telemetry, external
telemetry and hardwired amplifiers.
Cystometry (CYS)
Analyzes pressures resulting from non-voiding bladder
contraction cycles or longer time-scale pressure changes
resulting from bladder filling/voiding cycles.
• Peak Pressure • Base Pressure• Rise• Period • Peak Duration
• Inter-Contraction Interval • Duty Cycle • Time to Peak • Peak
C
ount • Peak Count Time • Area • Start Time • Peak Time • End
Time • Maximum Derivative • Minimum Derivative
Pulsatile Tissue and Gut Motility (PT)
Analyzes signals from isotonic or isometric transducers
from spontaneously or repetitively beating preparations.
• Maximum • Minimum • Average • Delta • Rate • Time to Peak
• +d_/dt • -d_/dt • %Recovery 1 • %Recovery 2 • +d’/dt • -d’/dt
• Motility Index • Area
NeuroScore
CNS Data Analysis Software
NeuroScore is a versatile, streamlined solution
that combines easy-to-use tools, efficient data
processing and accurate data analysis to reduce
time to results. Choose the CNS software modules
that best meet your research needs.
Sleep Scoring Modules
Dramatically reduce analysis time and variability using
the Rodent and Large Animal Sleep Scoring modules.
Automated Rodent Sleep Scoring
Scoring based on the frequency content of the EEG
and presence of EMG activity and movement.
Stages include: Paradoxical Sleep, Slow Wave Sleep
(SWS-1 and SWS-2), Wake and Active Wake.
Automated Large Animal Sleep Scoring
Based on the American Academy of Sleep Medicine
standards for human sleep scoring, this algorithm
uses EEG, EMG, EOG and activity data.
Stages include REM, Non-REM (N1, N2, N3), Wake,
and Active Wake.
Seizure Detection Module
The Spike Train detector scans the waveform
for repeating EEG spike activity via user-defined
amplitude-based criteria.
Several parameters including spike train duration
and number of spikes can be displayed per event
or summarized over longer time intervals.
Video Synchronization Module
Improve confidence in results by synchronizing video
data acquired with Dataquest A.R.T. or Ponemah to
validate or further classify detected events.
Batch Processing Module
Increase throughput by automating analysis processes
on multiple recordings at once. Customize workflows to:
Score multiple recordings
Export signal or parameter data
Generate and export reports
Complete these three steps within a single workflow
Multi-Lead Electrocardiogram (ECG)
Analyzes ECG signals to provide single and
multi-lead calculations.
• P, Q, S and T Wave Degree of Match using ECG PRO • Heart Rate
• R-R Interval • QT Interval • ST Interval • P-R Interval • QR Interval
• Q
RS Width • P Width • R, P and T Wave Heights • T Height Negative
• QR Amplitude • Variable ST Elevation • Q Alpha T Negative
• Multiple Corrected QT Calculations • QT Dispersion • +dV/dt Max
• T A
rea • P, T, QT and R Count • Bad, Good and Total Waves • T Peak
• T Peak Interval • Noise • Timing, Channel and Dispersion
Information Across Multiple Leads
Blood Pressure (BP)
Analyzes arterial and venous pressures.
• Systolic • Diastolic • Mean • Pulse Height • Heart Rate • Time to
Peak • Ejection Time • +dP/dt •-dP/dt • %Recovery • Non Pulsatile
Mean • Q-A Interval • Pulse Transit Time • Pulse Wave Velocity
• Inter-Beat Interval • Count
Blood Pressure Respiratory (BPR)
Derive respiration values from the cardiac cycle when
used in conjunction with the BP module.
• Respiration Rate • Interval
Left Ventricular Pressure (LVP)
Analyzes pressure signals from the left ventricle and
is used as a reference signal for other analysis modules,
such as Cardiac Volume.
• Systolic • LVEDP • Minimum Pressure • Time Tension Index
• Developed Pressure • Heart Rate • +dP/dt • -dP/dt • Contractility
I
ndex • Relaxation Times (1 & 2) • dP/dt at Selected Pressures
• Non Pulsatile Mean • Q-A Interval • IVT (Time from Systolic to
L
VEDP) • TTI-T (Time from LVEDP to –dP/dt) • Tau • Period
• Electromechanical Window • Count
Heart Rate Variability (HRV)
Analyzes the R-R intervals of ECG signals or
Inter-Beat-Intervals of blood pressure signals to convert
these time-based calculations to the frequency domain,
revealing the frequency components of the signals.
• Very Low Frequency (VLF) • Low Frequency (LF) • High Frequency
(HF) • Normalized LF and HF • LF/HF Ratio • Total Power
Cardiac Volume (CVOL)
Analyzes any volume from the circulatory system
and can derive values relative to the cardiac cycle.
• Heart Rate • Minimum Volume • Maximum Volume • Stroke
Volume • Volume at LVP Min Slope • Pressure at LVEDP • Volume
at LVEDP • Ejection Fraction • Peak Filling Rate • Peak Emptying
Rate • Time to Peak Filling Rate • Diastolic Filling Time • Time to
Peak Filling (Percentage) • Pressure at Max Elastance • Volume at
Max Elastance • Stroke Work • Arterial Elastance
Coronary Blood Flow (CBF)
Provides coronary flow and volume information
during systolic and diastolic periods in conjunction
with the LVP module.
• Mean • Flow Maximum • Flow Minimum • Cardiac Output • Stroke
Volume • +dQ • Systolic Flow • Diastolic Flow • Systolic Volume
• Diastolic Volume • -Flow • Total Volume • Non Pulsatile Mean
Automated validation marks for Q, R, S, End of T and Beginning
of P are shown. The validation marks provide visual, online
verification of the accuracy of the system.
Ponemah High Performance Analysis Modules
ECG PRO template library graph.
Mouse over cycle match. Can get visual information for each
cycle (how well it matched and to what template) by mousing
over the complex.
NeuroScore Workspace view for Sleep Scoring with Video Player.
Multiple templates can be used in a dataset and
templates can be added to a template library
for use in other studies
Accelerates the process of locating potential
arrhythmic beats
ECG Pattern Recognition Option (ECG PRO)
Greatly reduce processing time using ECG PROs
template-based analysis as it allows the selection
of a template cardiac cycle for precise comparison
to other cycles in the dataset.
Save time by only attempting to match unmatched
cycles or within specific regions
Automatically adjust the ECG waveform’s cycle
marks based on the template(s)
Systemic Blood Flow (SBF)
Analyzes systemic blood flow from the circulatory
system and eliminates drift resulting from certain types
of flow meters.
• Mean • Flow Maximum • Flow Minimum • Cardiac Output
• Stroke Volume • +dQ • Iso Flow • Total Peripheral Resistance
• Non Pulsatile Mean
PV Loop
Permits the display and analysis of LVP cycles
plotted against cardiac volume cycles.
Characterization of End Systolic Pressure Volume Relationship,
End Diastolic Pressure Volume Relationship and Pre-Recruitable
Stroke Work
Raw Electrical Mean
Analyzes any type of input signal that has no specific
analysis module. This module comes with the Ponemah
application.
• Mean • Maximum • Minimum • Period • Beats per Minute
• Area • Total Activity • Non Pulsatile Mean
Pulmonary Volume (PVO)
Analyzes pulmonary volume signals to derive
respiratory endpoints obtained from respiratory
impedance transmitters (D70-PCTR).
• Peak Inspiratory Flow • Peak Expiratory Flow • Tidal Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Apnea Time • Penh • Relaxation Time
• Tidal Volume (Expiration) • Inspiratory/Expiratory Flow 50%
• Accumulated Volume • Volume Baseline • Volume Fluctuation
• Flow Fluctuation • Median Tidal Volume • Median Tidal Volume
E
xpired • Tidal Volume Throughout • Tidal Volume Expired
Throughout • PZr Ratio
Pulmonary Air Flow and Airway Resistance (PAF)
Analyzes any pulmonary signal derived from a
plethysmography chamber, pneumotach or Jacketed
External Telemetry (JET™) Respiratory impedance bands.
• Peak Inspiratory Flow • Peak Expiratory Flow • Title Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Apnea Time • Specific Airway Resistance
• Phase Shift • Delay Time • Penh • Relaxation Time • Tidal Volume
(
Expiration) • Accumulated Volume • Inspiratory/Expiratory Flow
50% • Ratio EF/IF 50% • Apneic Interval
Unrestrained Plethysmography (URP)
Analyzes signals obtained from unrestrained whole
body plethysmography chambers. Includes the ability to
compensate for environmental conditions to calculate
adjusted volumes.
• Peak Inspiratory Flow • Peak Expiratory Flow • Tidal Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Pause • Penh • TVadj • MVadj • Apnea Time
• Apnea Count • Inspiratory/Expiratory Flow 50% • Ratio EF/IF 50%
• A
pneic Interval
Pulmonary Compliance & Resistance (PCR/PCRP)
Analyzes pulmonary signals from either a
plethysmographic chamber or a pneumotachometer,
along with a pressure, in anesthetized or conscious
animal models.
• Peak Inspiratory Flow • Peak Expiratory Flow • Tidal Volume
• Minute Volume • Respiration Rate • Inspiratory Time • Expiratory
T
ime • Total Time • Apnea Time • Resistance • Compliance
• Conductance • Multiple Resistances at Specified Points • Average
C
ompliance • Average Resistance • Pressures at Start of Inspiration/
Expiration • Flow and Pressure at Isovolumetric Points • Penh
• Relaxation Time • Work and Power of Breathing Calculations • Tidal
V
olume (Expiration) • Accumulated Volume • Inspiratory/Expiratory
Flow 50%
Diaphragmatic EMG (dEMG)
Analyzes diaphragmatic EMG signals to provide
respiratory endpoints.
• Respiration Rate • Tidal Volume* • Minute Ventilation*
• Inspiration Time • Expiration Time • Total Time
*
Tidal Volume and Minute Ventilation are only partial
representations as diaphragmatic activity is only a partial
representation of the respiratory mechanics.
Electromyogram (EMG)
Analyzes the electrical activity of muscle tissue.
• Integral • Peak
Action Potential (MAP)
Analyzes a host of action potentials with focus on
key regions such as plateau, recovery time and
upstroke velocity.
• Maximum • EDV • Minimum • Plateau • Amp • Rate • +dV
• -dV • Recovery 1 • xR1 • Recovery 2 • xR2 • Recovery 3 • xR3
• %Max • Time • Count • RiseT
Electroencephalogram (NeuroScore™)
DSI offers NeuroScore CNS analysis software for
sleep and seizure detection. NeuroScore is fully
compatible with the Ponemah system and can analyze
data collected by implantable telemetry, external
telemetry and hardwired amplifiers.
Cystometry (CYS)
Analyzes pressures resulting from non-voiding bladder
contraction cycles or longer time-scale pressure changes
resulting from bladder filling/voiding cycles.
• Peak Pressure • Base Pressure• Rise• Period • Peak Duration
• Inter-Contraction Interval • Duty Cycle • Time to Peak • Peak
C
ount • Peak Count Time • Area • Start Time • Peak Time • End
Time • Maximum Derivative • Minimum Derivative
Pulsatile Tissue and Gut Motility (PT)
Analyzes signals from isotonic or isometric transducers
from spontaneously or repetitively beating preparations.
• Maximum • Minimum • Average • Delta • Rate • Time to Peak
• +d_/dt • -d_/dt • %Recovery 1 • %Recovery 2 • +d/dt • -d’/dt
• Motility Index • Area
NeuroScore
CNS Data Analysis Software
NeuroScore is a versatile, streamlined solution
that combines easy-to-use tools, efficient data
processing and accurate data analysis to reduce
time to results. Choose the CNS software modules
that best meet your research needs.
Sleep Scoring Modules
Dramatically reduce analysis time and variability using
the Rodent and Large Animal Sleep Scoring modules.
Automated Rodent Sleep Scoring
Scoring based on the frequency content of the EEG
and presence of EMG activity and movement.
Stages include: Paradoxical Sleep, Slow Wave Sleep
(SWS-1 and SWS-2), Wake and Active Wake.
Automated Large Animal Sleep Scoring
Based on the American Academy of Sleep Medicine
standards for human sleep scoring, this algorithm
uses EEG, EMG, EOG and activity data.
Stages include REM, Non-REM (N1, N2, N3), Wake,
and Active Wake.
Seizure Detection Module
The Spike Train detector scans the waveform
for repeating EEG spike activity via user-defined
amplitude-based criteria.
Several parameters including spike train duration
and number of spikes can be displayed per event
or summarized over longer time intervals.
Video Synchronization Module
Improve confidence in results by synchronizing video
data acquired with Dataquest A.R.T. or Ponemah to
validate or further classify detected events.
Batch Processing Module
Increase throughput by automating analysis processes
on multiple recordings at once. Customize workflows to:
Score multiple recordings
Export signal or parameter data
Generate and export reports
Complete these three steps within a single workflow
Multi-Lead Electrocardiogram (ECG)
Analyzes ECG signals to provide single and
multi-lead calculations.
• P, Q, S and T Wave Degree of Match using ECG PRO • Heart Rate
• R-R Interval • QT Interval • ST Interval • P-R Interval • QR Interval
• Q
RS Width • P Width • R, P and T Wave Heights • T Height Negative
• QR Amplitude • Variable ST Elevation • Q Alpha T Negative
• Multiple Corrected QT Calculations • QT Dispersion • +dV/dt Max
• T A
rea • P, T, QT and R Count • Bad, Good and Total Waves • T Peak
• T Peak Interval • Noise • Timing, Channel and Dispersion
Information Across Multiple Leads
Blood Pressure (BP)
Analyzes arterial and venous pressures.
• Systolic • Diastolic • Mean • Pulse Height • Heart Rate • Time to
Peak • Ejection Time • +dP/dt •-dP/dt • %Recovery • Non Pulsatile
Mean • Q-A Interval • Pulse Transit Time • Pulse Wave Velocity
• Inter-Beat Interval • Count
Blood Pressure Respiratory (BPR)
Derive respiration values from the cardiac cycle when
used in conjunction with the BP module.
• Respiration Rate • Interval
Left Ventricular Pressure (LVP)
Analyzes pressure signals from the left ventricle and
is used as a reference signal for other analysis modules,
such as Cardiac Volume.
• Systolic • LVEDP • Minimum Pressure • Time Tension Index
• Developed Pressure • Heart Rate • +dP/dt • -dP/dt • Contractility
I
ndex • Relaxation Times (1 & 2) • dP/dt at Selected Pressures
• Non Pulsatile Mean • Q-A Interval • IVT (Time from Systolic to
L
VEDP) • TTI-T (Time from LVEDP to –dP/dt) • Tau • Period
• Electromechanical Window • Count
Heart Rate Variability (HRV)
Analyzes the R-R intervals of ECG signals or
Inter-Beat-Intervals of blood pressure signals to convert
these time-based calculations to the frequency domain,
revealing the frequency components of the signals.
• Very Low Frequency (VLF) • Low Frequency (LF) • High Frequency
(HF) • Normalized LF and HF • LF/HF Ratio • Total Power
Cardiac Volume (CVOL)
Analyzes any volume from the circulatory system
and can derive values relative to the cardiac cycle.
• Heart Rate • Minimum Volume • Maximum Volume • Stroke
Volume • Volume at LVP Min Slope • Pressure at LVEDP • Volume
at LVEDP • Ejection Fraction • Peak Filling Rate • Peak Emptying
Rate • Time to Peak Filling Rate • Diastolic Filling Time • Time to
Peak Filling (Percentage) • Pressure at Max Elastance • Volume at
Max Elastance • Stroke Work • Arterial Elastance
Coronary Blood Flow (CBF)
Provides coronary flow and volume information
during systolic and diastolic periods in conjunction
with the LVP module.
• Mean • Flow Maximum • Flow Minimum • Cardiac Output • Stroke
Volume • +dQ • Systolic Flow • Diastolic Flow • Systolic Volume
• Diastolic Volume • -Flow • Total Volume • Non Pulsatile Mean
Automated validation marks for Q, R, S, End of T and Beginning
of P are shown. The validation marks provide visual, online
verification of the accuracy of the system.
Ponemah High Performance Analysis Modules
ECG PRO template library graph.
Mouse over cycle match. Can get visual information for each
cycle (how well it matched and to what template) by mousing
over the complex.
NeuroScore Workspace view for Sleep Scoring with Video Player.
Multiple templates can be used in a dataset and
templates can be added to a template library
for use in other studies
Accelerates the process of locating potential
arrhythmic beats
Copyright© 2014 Data Sciences International
DSI is a pioneering biomedical research company focused on preclinical
systems physiology and pharmacology. The recognized global leader in
physiologic monitoring, DSI offers telemetry, instrumentation, software
and services that facilitate accelerated, well-informed drug therapy and
development decisions.
DSI serves many industries including: Pharmaceuticals, Academia,
Contract Research Organizations, Biological and Chemical defense, the
Medical Device Industry, Government and Biotechnology companies. We
offer solutions that are tailored specifically to meet the unique research
needs of our customers.
Headquarters and North American Sales:
1-800-262-9687 (U.S.)
1-651-481-7400 (International)
sales@datasci.com
datasci.com
European Sales:
Tel: 31-13-5479356
europe-sales@datasci.com
Asia Pacific Sales:
Tel: 86-21-50793177
DSI-shanghai-Office@datasci.com
Better Data. Better Science.
Better Data. Better Science.
About Data Sciences International
Ponemah
Analysis Modules
Start Studies Quickly with Help from
DSI Scientific Services
DSI can help you streamline your studies by providing
expertise you can trust. With our services, we can help
you meet your software validation GLP requirements,
achieve greater implanted telemetry success and
summarize data for confidence in your results.
Data Services
DSI will assist you with creating high quality, useable
reports that summarize your experimental data. The
reduction in time spent on data analysis and reporting
processes will provide you with more time to evaluate
the experimental results and plan your next logical
experiment.
Analysis expertise include hemodynamics, seizure
detection, sleep scoring and ECG evaluation
Comprehensive, useable results
Customized report package
Validation Services
Our experienced team offers a customized program
to help save time and reduce costs associated with
software systems validation.
Customized Validation Solutions Package (VSP) with
test scripts
Industry experienced GLP validation specialists
Contact us today for your free services consultation at
ScientificServices@datasci.com
Ponemah Analysis Modules
Trusted by researchers worldwide to discover
new insights into their research applications.
Confidence
Obtain accurate, consistent results via validated
algorithms developed from scientific and peer-
reviewed journals
Verify analysis accuracy with real-time visual feedback
Operate with full compliance within GLP environments
with the Ponemah Data Security Option (DSO)
Speed
Efficiently refine results by re-analyzing data
segments or manually editing mark placement
Automatically detect noise and eliminate it
from results
On-demand switching between time-based averages
or beat-to-beat data, which automatically export to
Microsoft Excel
®
or Access
®
Versatility
Easily configure modules to analyze various signal
types from any species
Instantly switch between time-based average or
beat-to-beat data
Solutions for all applications, including implantable
telemetry, jacketed telemetry and traditional
hardwired solutions
Copyright© 2014 Data Sciences International
DSI is a pioneering biomedical research company focused on preclinical
systems physiology and pharmacology. The recognized global leader in
physiologic monitoring, DSI offers telemetry, instrumentation, software
and services that facilitate accelerated, well-informed drug therapy and
development decisions.
DSI serves many industries including: Pharmaceuticals, Academia,
Contract Research Organizations, Biological and Chemical defense, the
Medical Device Industry, Government and Biotechnology companies. We
offer solutions that are tailored specifically to meet the unique research
needs of our customers.
Headquarters and North American Sales:
1-800-262-9687 (U.S.)
1-651-481-7400 (International)
sales@datasci.com
datasci.com
European Sales:
Tel: 31-13-5479356
europe-sales@datasci.com
Asia Pacific Sales:
Tel: 86-21-50793177
DSI-shanghai-Office@datasci.com
Better Data. Better Science.
Better Data. Better Science.
About Data Sciences International
Ponemah
Analysis Modules
Start Studies Quickly with Help from
DSI Scientific Services
DSI can help you streamline your studies by providing
expertise you can trust. With our services, we can help
you meet your software validation GLP requirements,
achieve greater implanted telemetry success and
summarize data for confidence in your results.
Data Services
DSI will assist you with creating high quality, useable
reports that summarize your experimental data. The
reduction in time spent on data analysis and reporting
processes will provide you with more time to evaluate
the experimental results and plan your next logical
experiment.
Analysis expertise include hemodynamics, seizure
detection, sleep scoring and ECG evaluation
Comprehensive, useable results
Customized report package
Validation Services
Our experienced team offers a customized program
to help save time and reduce costs associated with
software systems validation.
Customized Validation Solutions Package (VSP) with
test scripts
Industry experienced GLP validation specialists
Contact us today for your free services consultation at
ScientificServices@datasci.com
Ponemah Analysis Modules
Trusted by researchers worldwide to discover
new insights into their research applications.
Confidence
Obtain accurate, consistent results via validated
algorithms developed from scientific and peer-
reviewed journals
Verify analysis accuracy with real-time visual feedback
Operate with full compliance within GLP environments
with the Ponemah Data Security Option (DSO)
Speed
Efficiently refine results by re-analyzing data
segments or manually editing mark placement
Automatically detect noise and eliminate it
from results
On-demand switching between time-based averages
or beat-to-beat data, which automatically export to
Microsoft Excel
®
or Access
®
Versatility
Easily configure modules to analyze various signal
types from any species
Instantly switch between time-based average or
beat-to-beat data
Solutions for all applications, including implantable
telemetry, jacketed telemetry and traditional
hardwired solutions