Xybix Product Spec Sheet
LINAK TABLE RESET INSTRUCTIONS
Xybix Systems, Inc. • 8207 SouthPark Circle, Littleton, CO 80120 • 800.788.2810
Nov 2017
1. Unplug front or rear control box power cable from the Power Bar
mounted underneath the rear table or on the side of the CPU
cabinet. Need to wait a full 30 seconds for all power to drain from
control box.
2. Plug power cable back in and wait up to 1 minute for the power
to come back into the hand control. Next, make sure anything
under the work surface is cleared away (i.e. trash cans, equipment)
and hold the down button. Keep holding until it reaches the lowest
position and bounces up slightly. If table starts going crooked, stop
immediately, and call Xybix Customer Service at 720-382-2114 or
720-382-2122. If table resets fully, you should be able to adjust your
table to the appropriate height.
3. If this does not solve the problem, check that leg extension cables
are plugged in fully into the leg ports.
Xybix Product Spec Sheet
LINAK TABLE RESET INSTRUCTIONS
Xybix Systems, Inc. • 8207 SouthPark Circle, Littleton, CO 80120 • 800.788.2810
Nov 2017
4. Next, use the Allen wrench tool that came with your Xybix prod-
uct manual to get into the black lift case that is closest to the CPU
cabinet.
5. Check that the leg extension cables are plugged into the control
boxes tightly. There is a front control box with legs going into Port
2 on the bottom and Port 1 on the top. The rear control box could
have the same ports as the front OR an additional leg cable going
into Port 3 on the top – if the rear table has 3 legs).
6. Switch the port from A1 to A2 or vice versa for the hand control
extension cables in the black control box – for the front or the rear
table that is having the issue.
7. Unplug control box power cable again and try reset on the hand
control. If table starts going crooked or if this procedure doesn’t
work, stop immediately, and call Xybix Customer Service at
720-382-2114 or 720-382-2122.