6.Hold down "Set key" and "temp setting
key" for 5 seconds at the same time to
enter the Factory parameter setting mode,
press the "Lighting key” to change the
object, press "Set key(-)” and "temp setting
key(+)” to change the value. The system
will exit and save the parameters
automatically after 5 seconds without any
operation of keys.
( Model:X-300)
1.Press “Left Mixing Key”, turn on left
mixing function, left mixing light is on.
Press “Left Mixing key” again to turn off
the left mixing function.
2. Press “Right Mixing Key”, turn on right
mixing function, right mixing light is on.
Press “Right Mixing Key” again to turn off
the right mixing function.
3. Press the “Cold Drink key” (a Mixing
function must be turned on, otherwise the
Cold Drink key will not work), turn on the
cold drink function, and cold drink light is
on (the compressor is powered on) or cold
drink light flashes (compressor is powered
off), then press the “cold drink” key again
to close the cold drink function.
4. Press the Slush key (a Mixing function
must be turned on, otherwise the Slush
key will not work) to open the slush
function, and slush light is on (the
compressor is powered on) or slush light
flashes (compressor is powered off), then
press the Slush key again to close the slush
function.
5. Press the “Lighting key” to turn on the
light, and then press the “Lighting key”
again to turn off the light.
6.Press "Set key", enter the user parameter
setting state. At this time, press the Set key
to change the setting object, press
“lighting(-)” and “Adjust key(+)" to change
the value. After 5 seconds without
operating the key, the system will exit and
save the setting value automatically.
7.Hold down "Set key" and "Adjust key" for
5 seconds at the same time to enter the
Factory parameter setting mode, press the
"set" key to change the object, press “Set
key(-)" and "Adjust key(+)" to change the
value. The system will exit and save the
parameters automatically after 5 seconds
without any operation of keys.
( Model:X-450)
1.Press “Left mixing Key”, turn on left
mixing function, left mixing light is on.
Press “Left Mixing Key” again to turn off
the left mixing function.
2. Press “Mid Mixing Key”, turn on mid
mixing function, mid mixing light is on.
Press “Mid Mixing Key” again to turn off
the mid mixing function.
3. Press “Right Mixing Key”, turn on right
mixing function, right mixing light is on.
Press “Right Mixing Key” again to turn off
the right mixing function.
4. Press the “Cold Drink key” (a mixing
function must be turned on, otherwise the
Cold Drink key will not work), turn on the
cold drink function, and cold drink light is
on (the compressor is powered on) or cold
drink light flashes (compressor is powered
off), then press the “cold drink” key again
to close the cold drink function.
5. Press the Slush key (a Mixing function
must be turned on, otherwise the Slush
key will not work) to open the slush
function, and slush light is on (the
compressor is powered on) or slush light
flashes (compressor is powered off), then
press the Slush key again to close the slush
function.
6. Press the “Lighting key” to turn on the
light, and then press the “Lighting key”
again to turn off the light.
7. Press "Set key", enter the user
parameter setting state. At this time, press
the Set key to change the setting object,
press “Lighting(-)” and “Adjust Key(+)" to
change the value. After 5 seconds without
operating the key, the system will exit and
save the setting value automatically.
8.Hold down "Mid Mixing Key" and "Right
Mixing Key" for 5 seconds at the same time
to enter the Factory parameter setting
mode, press the "set" key to change the
object, press “Lighting key(-)" and "Adjust
key(+)" to change the value. The system
will exit and save the parameters
automatically after 5 seconds without any
operation of keys.
Notice: when machine works well, please
do not changed factory settings.
1.4.3 Alarm Code Description
1) 1, "- -": Frozen bowl alarm is given and
the compressor and motor will stop
working, and resume automatically after
10 minutes.
2) 2, "RH": temperature sensor
malfunction alarm. Stop cooling in cold
drink function state without affecting slush
function.
3)"LLL": low voltage alarm, the whole
machine stops. Turn off the power and
check the power supply. Restart machine
after voltage is stable. If it show “LLL”
frequently, We suggest you connect a
voltage stabilizer.
2. Safety
2.1 General Safety Rules
1. Read the entire manual carefully
2. The power cord must meet local safety
standards