Community Facilities/Houses of Worship
For all floors, show complete interior layouts and the following notes.
• “Interior layout as shown shall be substantially complied with, and all exits shall
be as approved by DOB.”
• “Maximum occupant load per floor/space shall be as approved by DOB.”
All Other Buildings/Uses:
For all floors, show layouts with exit corridors and stairs (as necessary), with the
following notes on each floor plan:
• “All partitions and exits shall be as approved by DOB.”
PCEs
In addition to the above notes, plans for PCEs should reflect the following
information/notes:
• “Minimum 3’0” wide exit pathways shall be provided leading to the required
exits. Pathways shall always be maintained unobstructed, including from any
gymnasium equipment.”
• “An approved interior fire alarm system shall be installed in the entire PCE space;
the system will include the following items:
− Area smoke detectors.
− Manual pull stations at each required exit.
− Local audible and visual alarms.
− Connection of the interior fire alarm to a FDNY approved central station.”
• “Local Law 58/87 shall be com
plied with as approved by DOB
Parking
Self Parking
Plans should show stalls that are a minimum 8’-6” wide and 18’-0” deep, with aisle
widths corresponding to the angle of parking stalls as required by recognized national
standards for parking lots/garages, (for example, the standard minimum aisle width for
90º parking stalls is 24’-0”).
End stalls parallel to walls or fences shall be a minimum 10’-0” wide.
Parallel parking shall have a minimum aisle width of 10’-0” and parking space
dimensions of 8-6” x 24’-0”.
Plans shall note: “All exits shall be as approved by DOB”.