Autronica Fire and Security
PRODUCTS 2017
Fire and gas safety
Division Petrochemical, Oil & Gas
Autronica Fire and Security is a leading innovator, manufacturer and supplier of
fire and gas safety worldwide. Our products ensure safety in applications on land,
sea and in the petrochemical, oil and gas sectors.
Owned by United Technologies Corporation (UTC), we employ more than
450 people handling the complete value chain, from idea, development and
manufacturing to the marketing, sales and servicing of our products. We are an
international company with worldwide oces and our HQ is located in Trondheim,
Norway’s technology hotspot.
Protecting life, environment, and property
Autronica Fire and Security AS
Division Petrochemical, Oil & Gas
Lagerveien 24
NO-4033 Stavanger
Norway
+47 90 90 55 00
oil.gas@autronicafire.no
www.autronicafire.com
WORLDWIDE SERVICE ASSISTANCE
Phone: +47 915 09753
E-mail:service.oilgas@autronicafire.no
SPARE PARTS
Phone: +47 90 90 55 00
E-mail: spareoil.gas@autronicafire.no
24 HOUR SUPPORT – END USERS ONLY
Phone: +47 48 25 80 00
AutroSafe integrated fire and gas ...................... 4
Panels................................................................6
Panel kits............................................................. 7
Loop panels ..........................................................8
Switches and converters ..............................................8
Printer ..............................................................10
I/O modules ..........................................................11
Communication..................................................... 13
OPC server ..........................................................14
Integrated fire and gas (IFG) modules .................................14
Cabinets and racks................................................... 15
Mounting accessories for cabinets and racks .......................... 15
Batteries............................................................. 16
Power supply units ..................................................16
Cables............................................................... 17
Relays............................................................... 17
Customer configuration ............................................. 17
AutroMaster presentation system ..................... 18
Software licences ....................................................20
Software modules....................................................20
Interface modules ...................................................21
Software hardcopies .................................................21
Engineering ......................................................... 21
Hardware ...........................................................22
Loop units .......................................... 24
Input and output units ...............................................25
Control units ........................................................29
Detectors............................................................30
Manual call points and release stations................................32
Alarm units..........................................................35
Door magnet ........................................................40
Accessories for loop units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Service tools for detection loops ......................................42
Flame detection ....................................44
Flame detectors......................................................45
Cable glands/Blind plugs.............................................46
Accessories..........................................................46
Test equipment......................................................47
Gas detection .......................................48
Infrared hydrocarbon gas detectors...................................49
Acoustic gas detectors ...............................................50
Toxic gas detectors ..................................................51
Toxic gas sensor modules ............................................ 51
Display units ........................................................52
Toxic gas transmitters and termination boxes . . . . . . . . . . . . . . . . . . . . . . . . . 52
Accessories..........................................................53
Calibration kits ......................................................54
Accessories for calibration kits .......................................54
Other detectors ..................................... 56
Alarmline linear heat detectors .......................................57
Accessories..........................................................57
Aspirating detectors .................................................57
Accessories..........................................................59
Piping – halogen free ................................................59
Beam detectors ......................................................64
Accessories..........................................................64
Omicron systems....................................66
Point gas detection system – OGS 2.1 .................................67
Gas sampling system – OGS 3.1 ......................................69
OGS shale shaker ....................................................72
OGS direct sampling .................................................73
Standard accessories.................................................74
Stringent control throughout Autronica Fire and Security AS assures the excellence of our products and services.
For a complete overview of our approvals, go to www.autronicafire.com.
Contents
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
4
AutroSafe IFG
– a complete solution
for fire and gas detection
AutroSafe integrated fire and gas
More than ten years with SIL 2 certification
Our task was demanding, yet simple: Take the best fire and gas (F&G)
safety system around and make it even better. The AutroSafe Integrated
Fire and Gas (IFG) 4 is designed for the toughest requirements and
expands the possibilities of a F&G detection system even further. From
oshore platforms to LNG plants to refineries, AutroSafe IFG delivers the
most rigorous F&G safety yet.
Autronica Fire and Security launched AutroSafe, our high-end fire
detection system, in 1999. From day one, AutroSafe has proven its
unique stability and reliability in more than 15 000 of installations
worldwide, both on- and oshore. AutroSafe IFG 4 provides advanced
functionality for a wide range of applications. The system is designed
to meet all requirements in the high-end segment of the oshore
market. It is certified according to European directives (CPD) requiring
EN 54 compliance, and is approved by Factory Mutual (FM) according
to NFPA 72. Additionally, the F&G system is approved according to SIL2
requirements by TÜV Nord.
Reliable communication is paramount to your safety. That’s why we’re
adding AutroNet to the AutroSafe IFG system, an innovative network
solution safeguarding communication between panels. AutroNet
ensures a redundant and high-speed network, expanding the reach of
the AutroSafe IFG system even further. The system can be set up either
in a star or ring network, depending on your needs.
History proves you can rely on AutroSafe IFG. All existing functionality
has stood up to the toughest tests worldwide for more than 10 years.
With AutroSafe IFG 4, Autronica has once again taken fire safety to a
higher level.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
5
AutroSafe integrated fire and gas |
Architectural example
Fire & gas
control panel
Repeater
panel
Switch
HMI: AutroMaster
ISEMS
Standard
AutroSafe
loop units
IS isolator unit
AutroSafe
IS loop units
AutroFlame
detector
AL_Com loop
AutroPath
gas detectors
AutroPoint
gas detector
Controller
Operator
panel
AutroSense
aspirating detector
PowerLoop
AutroNet A
AutroNet B
Information
loop panel
Information
loop panel
Repeater
panel
Safety PLC
Autronica Fire and Security AS
has once again taken fire safety
to a higher level
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
6
Panels
The AutroSafe family consists of four dierent panel types. These are:
Fire alarm control panel, BS-420. BS-420 is the main panel in the AutroSafe family. It can be used as a stand-alone panel as well as part of a network
system. All operations, alarm management, indications and other functions within an operation zone are controlled and handled by the panel. The
panel is equipped with a display, light indicators, a numeric keypad, a navigation wheel and special function buttons (e.g. Silence Alarms). Loop driver,
input and output modules can be connected. An integrated AutroFieldBus interface makes it possible to connect AutroFieldBus equipment to the
panel. All AutroSafe systems must include at least one BS-420 panel.
Operator panel, BS-430. As for the BS-420 panel, all operations, alarm management, indications and other functions within an operation zone are
controlled and handled by the BS-430 panel. The panel is equipped with a display, light indicators, a numeric keypad, a navigation wheel and special
function buttons (e.g. Silence Alarms). No loop driver, input or output modules can be connected to this panel.
Controller, BC-420. The BC-420 serves as a connection unit for loop driver modules as well as input and output modules. It is equipped with two light
indicators for System Fault and Power. The panel has neither display nor operator buttons. An integrated AutroFieldBus interface makes it possible to
connect AutroFieldBus equipment to the panel.
Controller rack unit BC-440. Serves as a connection unit for the detection loop, alarm sounders, controls and inputs. It is a variant of the BC-420
prepared for rack installations. Together with the I/O modules the unit will have the full functionality of the BC-420. Equipped with 2 Ethernet ports,
one AutroFieldBus port and one serial port.
Repeater panel, BU-BV-420. Physical dip-switches on the panel control the BU-BV-420 panel function. As an alarm operation panel it can operate
alarms within one or more operation zones. As an information panel no operation of alarms are available. The information panel provides information
from one or more operation zones.
In addition to the panels the power cabinet BP-405 is a part of the AutroSafe 4 family. The cabinet includes a 5 A power pack (BPS-405) which provides
six 24 VDC / 2 A outputs. The input voltage is 115 / 230 VAC and the total maximum power available is 24 VDC / 5 A. An integrated AutroFieldBus interface
makes it possible for the power pack to communicate (send fault messages) with the BS-420 or BC-420 panel. The cabinet provides space for two 12 V /
18 Ah batteries (not included).
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
7
AutroSafe integrated fire and gas | Panel kits
Panel kits
An Al_Com+ stack can contain up to six loop driver modules (BSD-3xx). By using AutroFieldBus, an additional Al_Com+ stack (with up to six additional
loop driver modules) can be added to the system.
NOTE! The AutroSafe panels are certified with the Al_Com+ modules mounted inside the panel cabinet.
Image Part number Description Including Options
116-KIT-BS-420G
Fire alarm control
panel kit
Panel front BSV-420G
Cabinet UEA-400
Power supply module BSS-310A
Communication module BSL-310
Text foils E-2879/GB-G
Loop driver module BSD-310
Loop driver module H.P. BSD-311
BS-100 loop driver module BSD-330
Output module BSB-310A
Output module BSJ-310
Input module BSE-310
Input module BSE-320
Dual power mon. module BSS-311
Dual serial communication ports
116-KIT-BS-420G2
Fire alarm control
panel kit approved
acc. to IEC 61508
SIL2
116-KIT-BS-420ASAP
Fire alarm control
panel
With ASAP converter. Contact your sales representative for further details
116-KIT-BC-420 Controller kit
Panel front BCV-420
Cabinet UEA-400
Power supply module BSS-310A
Communication module BSL-310
Text foils E-2880/GB-G*
Loop driver module BSD-310
Loop driver module H.P. BSD-311
BS-100 loop driver module BSD-330
Output module BSB-310A
Output module BSJ-310
Input module BSE-310
Input module BSE-320
116-KIT-BC-420G2
Controller kit
approved acc. to
IEC 61508 SIL2
116-BC-440 Controller rack unit
116-BC-440G2
Controller rack unit
approved acc. to
IEC 61508 SIL2
116-KIT-BS-430 Operator panel kit
Panel front BSV-420
Cabinet UE-1488
Text foils E-2879/GB-G*
116-KIT-BS-430G2
Operator panel kit
approved acc. to
IEC 61508 SIL2
116-KIT-BU-BV-420 Repeater panel kit
Panel front BUV-420
Cabinet UE-1489
Text foils E-2880/GB-G*
116-KIT-BU-BV-420G2
Repeater panel kit
approved acc. to
IEC 61508 SIL2
116-BP-405 Power cabinet
Cabinet UEA-410
5 A / 24 V power unit BPS-405
Available space for 2 x 12 V / 18 Ah
batteries
*: Please specify language GB-G when ordering
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
8
Loop panels
We have now included loop-powered panels in our portfolio, providing our customers a number of advantages: Quicker installation, reduced cabling and
cost, and lowered system complexity. A detection loop can accommodate up to eight loop panels.
Image Part number Description
Dimensions
H x W x D (mm)
Current
consumption Notes
116-KIT-BU-110
Fire brigade loop panel
kit*
310 x 154 x 45
<1 mA (idle)
6 mA (max)
Enables silencing the
panel’s internal buzzer,
silencing alarms, and
resetting the system.
Alarms only are shown
in the display.
116-KIT-BV-110
Information loop panel
kit*
310 x 154 x 45
<1 mA (idle)
6 mA (max)
Indication device only.
Provides information
related to the defined
operation zone(s).
* Please specify language when ordering
GB = English
E = Spanish
F = French
H = Hungarian
I = Italian
IS = Icelandic
BR = Portuguese
PL = Polish
RK = Russian
SF = Finnish
NL = Dutch
DK = Danish
S = Swedish
N = Norwegian
Switches and converters
A network solution (AutroNet) with more than two panels demands the use of switches. Fibre converters are utilized to extend your network where
fibre is available. VDSL converters are utilized to make use of existing copper wiring when upgrading old systems. Only the listed Ethernet switches
and converters are approved and supported by Autronica Fire and Security AS. The type and number of switches/converters depend on the installation/
network construction (no. of panels and distance between panels and switches/converters).
Image Part number Description*
Current
consumption
(max.)
@ 24 VDC
RJ45
ports
Fibre optic
ports**
Operating
temperature
116-5151-030.2127 FL switch SFNT 5TX
120 mA 5 -40 - 75°C
116-5151-030.2128 FL switch SFNT 4TX/FX 160 mA 4 1 MM (SC) -40 - 75°C
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
9
AutroSafe integrated fire and gas | Switches and converters
Image Part number Description*
Current
consumption
(max.)
@ 24 VDC
RJ45
ports
Fibre optic
ports**
Operating
temperature
116-5151-030.2129 FL switch SFNT 8TX 153 mA 8 -40 - 75°C
116-5151-030.2130 FL switch SFNT 7TX/FX 175 mA 7 1 MM (SC) -40 - 70°C
116-5151-030.2131 FL switch LM 5TX 150 mA 5 -40 - 70°C
116-5151-030.2132 FL switch LM 4TX/FX 380 mA 4 1 MM (SC) -40 - 70°C
116-5151-030.2133 FL switch LM 4TX/2FX 400 mA 4 2 MM (SC) -40 - 70°C
116-5151-030.2134 FL switch LM 4TX/FX SM 380 mA 4 1 SM (SC) -40 - 70°C
116-5151-030.2135 FL switch LM 4TX/2FX SM 400 mA 4 2 SM (SC) -40 - 70°C
116-5151-030.2142
FL switch SFNB 4TX/FX
SM 20
185 mA 4 1 SM (SC) 0 - 60°C
* SFNT = Standard Function, Narrow housing, high Temperature range
LM = Lean Managed
SFNB = Standard Function, Narrow housing, Basic entry level
SFN = Standard Function, Narrow housing
** MM = Multi Mode
SM = Single Mode
SC = Square Connector
(Set and Click, Stab and Click, Standard Connector)
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
10
Image Part number Description*
Current
consumption
(max.)
@ 24 VDC
RJ45
ports
Fibre optic
ports**
Operating
temperature
116-5151-030.3001
Jetcon 1301-S single mode
fibre converter
150 mA 1 1 SM (SC) -40 - 70°C
116-5151-030.3002
Jetcon 1301-M multi mode
fibre converter
150 mA 1 1 MM (SC) -40 - 70°C
116-5151-030.3003
Jetcon 2502 ethernet/VDSL 2
converter
210 mA 2 -40 - 70°C
* SFNT = Standard Function, Narrow housing, high Temperature
range
LM = Lean Managed
SFNB = Standard Function, Narrow housing, Basic entry level
SFN = Standard Function, Narrow housing
** MM = Multi Mode
SM = Single Mode
SC = Square Connector
(Set and Click, Stab and Click, Standard Connector)
Printer
Image Part number Description
116-BUP-400 Log printer unit for AutroSafe 4
116-1712-012.0001 Printer paper 57 x 46 x 13 mm / 25 m
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
11
AutroSafe integrated fire and gas | I/O modules
I/O modules
AutroSafe IFG features input and output modules for dierent applications (monitored alarm loops, servicing relays and LEDs, control inputs, etc.). The
modules have the same format, mount onto the panels’ DIN-mounting rail and plug into one another.
Important note on module capacity.
Each fire alarm panel/controller contains a power supply module BSS-310A and a communication module BSL-310.
The BS-420 and BC-420 panels have space for up to 12 modules totally inside the cabinet.
An Al_Com+ stack can contain up to six loop driver modules (BSD-3xx)
By using AutroFieldBus, an additional Al_Com+ stack (with up to six additional loop driver modules) can be added to the system.
NOTE! The AutroSafe panels are certified with the Al_Com+ modules mounted inside the panel cabinet.
Image Part number Description
Monitored inputs
Monitored outputs
Total inputs
Total outputs
Monitors short circuits
Ensures loop communication
For use in EX zone 2 only
Amplified power output
Maximum per panel
Notes
116-BSB-310A Output module
0 4 Requires external 24V
116-BSD-310 Loop driver module 6/12 Max. 127 loop units
116-BSD-310/N Loop driver module 6/12 Max. 127 loop units
116-BSD-311
Loop driver module
H.P.
6/12
116-BSD-330
BS-100 loop driver
module
8
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
12
Image Part number Description
Monitored inputs
Monitored outputs
Total inputs
Total outputs
Monitors short circuits
Ensures loop communication
For use in EX zone 2 only
Amplified power output
Maximum per panel
Notes
116-BSE-310 Input module 4 0
116-BSE-320 Input module 8 0
Galvanically insulated
inputs
116-BSJ-310 Output module 0 8 Open transistor outputs
116-BSS-310A Power supply module 3
116-BSS-311
Dual power monitoring
module
2
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
13
AutroSafe integrated fire and gas | Communication
Communication
Image Part number Description
116-BSD-321/1
AutroFieldBus protocol converter
Interface between AutroFieldBus and Al_Com+. Enables communication between all Al_Com+
modules in an Al_Com+ stack connected to AutroFieldBus. The module enables AutroSafe
DualSafety configuration, with both ordinary Al_Com communication and AutroFieldBus.
116-BSL-310
AutroSafe communication module, serves as an interface for the common internal communication
line between all the dierent I/O modules. Part of the fire alarm control panel.
116-BSL-321
Multi mode fibre optic converter
Amplifier for AUTROLON/AutroFieldBus networks, which acts as a fibre optic modem. The
converter ensures reliable communication for distances of up to 3000 m. Uses multi-mode
(62.5/125 µm or 50/125 µm) fibre-optic cable. Ingress Protection level: IP20
116-BSL-322
Single mode fibre optic converter
Amplifier for AUTROLON/AutroFieldBus networks, which acts as a fibre-optic modem. The
converter ensures reliable communication for distances of up to 15000 m. Uses single-mode (9/125
µm) fibre-optic cable. Ingress Protection level: IP20
116-BSL-325
AUTROLON/AutroFieldBus communication amplifier
Amplifier for communication signals on networks. The amplifier ensures reliable communication
in systems where there is great distance between the system panels, and in applications where
there are many panels. The amplifier increases maximum cable length from 1000 m to 2800 m.
Ingress Protection level: IP20
116-BSL-337
AutroSafe BU-70 interface module
Enables the connection of BU-70/BU-100/BU-101 to AutroSafe. This is a simple, cost eective way
to upgrade BS-100 systems to AutroSafe. The RS232/20 mA current loop converter BSL-12/2 must
be used to convert RS232 to 20 mA current loop communication.
Ingress Protection level: IP20
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
14
OPC server
Part number Description
116-AS-OPC-SERVER/CD1
AutroSafe OPC server CD V1.2 incl. access code for access level 1. Includes read access to all status information for
detectors, output and alarm devices. This level of license will also make it possible to send (write) Silence, Reset and
SetTime commands to the AutroSafe system. Within this level you can also Disable/Enable detectors.
116-AS-OPC-SERVER/CD2
AutroSafe OPC server CD V1.2 incl. access code for access level 2. Includes all functionality in level 1, plus the
possibility to Activate/Deactivate and Enable/Disable outputs and alarm devices via OPC write commands.
116-AS-OPC-SERVER/CD3
AutroSafe OPC server CD V1.2 incl. access code for access level 3. Includes all functionality in level 1 and 2.
This level also provides additional information for points, for example AMEAS, Temp, Smoke, Alarm limits and
Engineering values.
Integrated fire and gas (IFG) modules
Image Part number Description
116-BN-342/1
PowerLoop 4-20 mA input unit, rack mounted
A general-purpose PowerLoop interface designed for third-party detectors connected to the
AutroSafe IFG system. The unit has a 4-20 mA input galvanically isolated from the PowerLoop. 19”
3U rack version, bare PCB with 19” rack front panel, no DC/DC. Ingress Protection level: IP20
116-BN-342/2
PowerLoop 4-20 mA input unit, DIN rail mounted
A general-purpose PowerLoop interface designed for third party detectors connected to the
AutroSafe IFG system. The unit has a 4-20 mA input galvanically isolated from the PowerLoop. DIN
rail version, bare PCB in an open DIN rail box, no DC/DC. Ingress Protection level: IP20
116-BN-342/EX
PowerLoop 4-20 mA input unit, field mounted
A general-purpose PowerLoop interface designed for third party detectors connected to the
AutroSafe IFG system. The unit has a 24 VDC/400 mA supply output providing power to the
connected detectors, plus a 4-20 mA input galvanically isolated from the PowerLoop. EEX me
version including 9,5 W 24 VDC/DC for external detector power supply.
Cable entry, PowerLoop: 2 x M25. Cable entry, 4-20 mA input: 1 x M25
Ingress Protection level: IP66
116-BSD-340/1
PowerLoop driver module, rack mounted
The module has a capacity of up to 15 detectors connected directly with protocol interface or
through interface unit (BN-342/XX). The number of detectors must be verified by means of a
PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the
AutroFieldBus driver (EAU-341). Ingress Protection level: IP20
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
15
AutroSafe integrated fire and gas | Cabinets and racks
Image Part number Description
116-BSD-340/2
PowerLoop driver module, DIN rail mounted
The module has a capacity of up to 15 detectors connected directly with protocol interface or
through interface unit (BN-342/XX). The number of detectors must be verified by means of a
PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the
AutroFieldBus driver (EAU-341). Ingress Protection level: IP20
116-BSD-340/EX
PowerLoop driver, for hazardous areas, zone 1 and 2, field mounted
The module has a capacity of up to 15 detectors connected directly with protocol interface or
through interface unit (BN-342/XX). The number of detectors must be verified by means of a
PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the
AutroFieldBus driver (EAU-341). Dimensions of entries: 5 x M20, 1 x M25.
Ingress Protection level: IP66
Cabinets and racks
Part number Description
Dimensions
H x W x D
(mm) Notes
116-UEA-323/1 Cabinet for flush mounting BS-410/-420/BC-420 320 x 320 x 140
Mounting accessories for cabinets and racks
Module height unit = 44.5 mm. Width unless specified otherwise = 48.3 mm.
Rittal cabinets or equivalent are available on request.
Part number Description
Dimensions
(mm)
Height units
Notes
116-UB-383 19” subrack, Europe
w = 160 3
116-UW-1454 Mounting kit for 19’’ cabinet/rack. Front panel. h = 399 9 For BS-420 w/cabinet UEA-323/1
116-UW-1482 Mounting kit for 19’’ cabinet/rack. Front panel h = 266 6 For BU-BV-420
116-UW-1454
Mounting plate for flush mounting panel front in 19” cabinet/
rack
h = 399 9 For BS-420/-430 and BC-420
116-UW-1516/1 Dummy plate 19” h x w = 128 x 60 3 For BC-440
116-UW-1518 Mounting plate h x w = 622 x 455
For mounting AutroSafe 4 front
panel on double BS-100 cabinet
116-UE-1662 Spacer (between 2 rack mounted panels) h x w = 80 x 137.5
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
16
Batteries
Autronica Fire and Security AS oers accumulator batteries for every Autronica fire alarm system. Generally, 24 VDC back-up is used, this requires two
batteries per panel. All batteries are sealed and can be placed in cabinets.
Part number Description Voltage Weight
Dimensions
L x W x H
116-4160-001. FIAMM FG20721 12 V / 7.2 Ah 2,4 kg 79 x 56 x 106 mm
116-4160-002. FIAMM FG21803 12 V / 18 Ah 5,9 kg 181 x 76 x 167 mm
116-4160-003. FIAMM FG22703 12 V / 27 Ah 8,7 kg 166 x 175 x 125 mm
116-4160-004. FIAMM FG24204 12 V / 42 Ah 13,8 kg 196 x 163 x 174 mm
116-4160-005.0001 FIAMM FG21202 12 V / 12 Ah 4,0 kg 151 x 98 x 99 mm
116-4160-005.0003 FIAMM FG20341 12 V / 3 Ah 1,41 kg 134 x 67 x 60 mm
116-4160-006. FIAMM FG27004 12 V / 70 Ah 22,7 kg 350 x 166 x 174 mm
116-4160-006.0001 Sonnenschein A512/115 12 V / 115 Ah 40,0 kg 286 x 269 x 230 mm
116-4160-006.0003 Sonnenschein A512/85 12 V / 80 Ah 31,0 kg 330 x 171 x 236 mm
116-4160-006.0004 Sonnenschein A115/200 12 V / 200 Ah 70,0 kg 518 x 274 x 242 mm
Power supply units
Part number Description Output voltage
116-BPS-405/BOXED Power supply unit for AutroSafe 4 24 VDC / 5 A
116-BPS-410/BOXED Power supply unit for AutroSafe 4 24 VDC / 10 A
116-BPS-410/115/BOXED Power supply unit for AutroSafe 4, 115 VAC 24 VDC / 10 A
116-4550-012.2410
Power supply for AutroSafe, for additional power. Temperature
compensated battery charging
27,3 VDC / 10 A
116-4660-009.0004 DC/DC converter 24 VDC / 3 A
116-4660-016.0001 DC/DC converter MINI-PS 12-24 DC / 24 DC1 24 VDC / 1 A
116-4660-055.0001 DC/DC converter 24 VDC / 6,3 A
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
17
AutroSafe integrated fire and gas | Cables
Cables
Part number Description
116-XJA-027
Connection cable for AS 2000; for connection between PC and fire alarm panel
(AS-SYSUTILPAC includes this item)
116-XGE-1/10-XX Ribbon cable. Optional lengths: 40 or 110 cm. Replace XX with length
116-XL-073 Conversion cable from AutroSafe 3 to AutroSafe 4
Relays
Part number Description
116-7624-030.0001 Relay PLC RSC 24 DC/21, single change-over contact
116-7624-030.0002 Relay PLC RSC 24 DC/21-21, double change-over contact
Customer configuration
Part number Description
116-PROG-AUTROSAFE Customer specific software for AutroSafe
116-TXT-AUTROSAFE Customer texts/controls
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
18
AutroMaster presentation system
A fully integrated safety and emergency management system
The AutroMaster is an integrated safety and emergency management
system combining the strengths of a powerful fire detection system with
control and monitoring functions dedicated to make sure you are in
control in case of an emergency.
Graphical user interface
The AutroMaster provides an intuitive control and monitoring interface
built to save valuable time when every second counts. Status information is
displayed in real-time with easy-to-understand graphical representation.
Navigation is fast and instinctual and the powerful zoom functions allow
you to monitor all areas in great detail.
AutroMaster displays values for smoke density and heat in dynamic colours,
making it easy to perform the necessary actions during emergencies.
Interoperability
Control and monitoring of third party systems can easily be performed via
serial protocols or network interfaces. They provide connection to basically
any source – network time servers, telephone systems for text messaging,
public address systems for automated voice messaging, emergency lights,
access control systems, CCTV, automation systems and so on.
Logging and reporting
The AutroMaster keeps track of all events in the system and has a built-in
report generator. This provides a cost-eective system log for maintenance
and documentation purposes.
Decision-making tools
In high-risk environments around the world, a seemingly innocuous
fire can quickly escalate into an emergency of large proportions. When
disaster strikes and you only have seconds to make the proper decisions,
the right safety and emergency management system is an invaluable
asset. The AutroMaster includes a Decision Support System (DSS) that will
help you make the right decisions at the right time.
Easy to use,
provides full overview
and saves valuable time
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
19
AutroMaster presentation system
AutroMaster editions
AutroMaster ISEMS is the complete AutroMaster edition, including all functionality. In addition, we oer a market specific edition with the modules most
relevant for the oil and gas market
Modules/functions
AutroMaster
POG edition
AutroMaster
ISEMS
Basic functionality
Fire management basic functions
MultiSensor control
Report generator
Control and monitoring of emergency lights/LLL
Extended functionality
AutroSafe IFG unit support
Touch screen support
Decision support system/incident manager
Electronic plotting table
Training/simulation module
Event record and replay module
Video module (live video support CCTV)
Remote connect function
Message centre module
Interfaces
Hernis CCTV interface
System-S interface
NMEA interface
VDR output
MODBUS interface
ESPA 4.4.4 interface
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
20
Software licences
Part number Description
116-PROG-AUTROMASTER-POG
AutroMaster Oil & Gas Edition –
For the Petrochemical, Oil and Gas market applications, support for the SIL2
approved AutroSafe IFG panel is mandatory. The AutroMaster Oil & Gas Edition is specially designed to use the
AutroSafe IFG functionality to among other functions provide gas trending and LEL indication.
116-PROG-AUTROMASTERISEMS
AutroMaster ISEMS – Provides the full range of functionality – every possible add-on module is included
in this package, making it the perfect choice for demanding applications and professional customers.
116-PROG-AM-UPGRADE
Upgrade of AutroMaster to most recent version – Existing AutroMaster customers can upgrade their
license to the most recent version of AutroMaster. Requires change of AutroMaster configuration data.
Software modules
Part number Description
116-PROG-AM-MOD-DSS
Decision Support System (DSS) – An interactive incident management system for AutroMaster. The DSS
gives operators access to customer-specified checklists. The checklists are organized as checkpoints with
one or more action items that can be used to manage operations, and these can be marked o as actions
are completed.
116-PROG-AM-MOD-EPTABLE
Electronic fire control plotting table – gives you a dynamic plotting table to keep track of actors events
during an emergency or drill. All EPT activity is logged in the Decision Support System and is available for
later reviews.
116-PROG-AM-MOD-TSIM
Training/Simulation module – A tool to simulate pre-configured events. During a simulation it is possible
to pause, stop/end, and continue the simulation. Running the simulation tool is similar to running a live
event, alarms and faults are acknowledgeable and resettable. Every event is logged, and after a simulation
(or a stop), a full log can created and it is possible to replay the simulation using the Event record/replay
module.
116-PROG-AM-MOD-EVENT
Event Record/Replay module – Oers a screenshot-based replay of incidents on AutroMaster and can be
configured to start recording manually or on pre-configured events as pre-warning, alarm or simulation.
Recordings are available for replay, and under replay the operator can start, stop, pause, fast-forward and
fast backwards. It is possible to export stored events.
116-PROG-AM-MOD-VIDEO Video interface module – Includes display of live video in AutroMaster from IP based video cameras.
116-PROG-AM-MOD-REMOTE
Remote Connect function – The Remote Connect Module enables a remote connection to AutroMaster
from any location using a server/client technology.
116-PROG-AM-MOD-MC
Message Centre module – In the Message Centre the user can send text messages to telephone systems
and other AutroMaster PCs. The user can also send pre-recorded voice messages to PA systems. Requires
ESPA 4.4.4. interface.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
21
AutroMaster presentation system | Interface modules
Interface modules
Part number Description
116-PROG-AM-MOD-HERNIS
Hernis CCTV interface – Interface enables use of AutroMaster together with video cameras and servers
from Hernis.
116-PROG-AM-MOD-NMEA
NMEA interface – A protocol used for interface in between maritime electronic equipment, and
AutroMaster has built-in support for this in the NMEA interface module. Interface towards GPS is the most
common application.
116-PROG-AM-MOD-VDROUTPUT
VDR output – Used in maritime applications for giving output to the Voyage Data Recorder. Configuration
of which data and status messages to send to the VDR is done by project engineering.
116-PROG-AM-MOD-MODBUS
MODBUS interface – With the MODBUS interface AutroMaster can be connected to almost any kind of
electronic equipment for monitoring and control.
116-PROG-AM-MOD-ESPA444
ESPA 4.4.4 interface – Oers a serial protocol intended for the interconnection of paging equipment with
telephone exchanges or computer systems. The protocol used is message-based and is built upon the
ISO1745 transport specification. Required if Message Centre module is used.
Software hardcopies
Part number Description
116-AUTROMASTER-POG-CD AutroMaster POG back-up CD without licence
116-AUTROMASTERISEMS-CD AutroMaster ISEMS back-up CD without licence
Engineering
Part number Description
116-PROSJAMD Adding of detectors to drawings
116-PROSJAMDF Adding of color fill for analog values
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
22
Hardware
Part number Description
116-AUTROMASTER-PC-12 PC , desktop version, convertible minitower. Model subject to change without prior notice.
116-AUTROMASTER-RACKPC 19" rack mounted PC
116-5151-020.0210 Industrial PC w/SSD
116-5151-020.1951 19" standard LCD monitor (1280 x 1024 resolution)
116-5151-020.2405 24" widescreen LCD monitor (1920 x 1200 resolution)
116-5151-200.0023 20” monitor, console mounted, JH20T17 MMD
116-5151-017.0004 Keyboard/mouse Nordic character set
116-5151-017.0002 Keyboard - UK/English character set
116-5151-020.0400 Mouse - USB - 3 buttons
116-5760-050.2003 Laser printer, colour, network and USB
116-5151-020.0732 Network card TG-3468 10/100/1000
116-5151-020.2029 Moxa 4-port serial PCIE
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
24
We provide a wide range of loop units for our fire detection systems. Our
detectors, manual call points, I/O units, control units and alarm units are
developed and approved according to European directives (CPD) requiring
EN 54 compliance and other appropriate worldwide regulations.
The loop units are available both with and without SelfVerify function.
SelfVerify solves all issues of manual maintenance, leaving time consuming
and costly physical testing redundant. With AutroSafe SelfVerify®, the
system checks all detectors, interfaces, connections and cables – from
detector chamber to alarm output – every single day.
Not only does the system test whether a detector is capable of provoking
an alarm, it even verifies the sensitivity of every detector with a calibrated
signal. The SelfVerify system ensures that each detector always responds
to the correct alarm level. In the event of irregularities, the display on the
operating panel will accurately pinpoint the source of any problem.
SelfVerify ensures that you have the safest and most reliable fire safety
system available – a system ensuring optimal detection.
Loop units
A wide range covering your basic fire detection needs
SelfVerify ensures
optimal detection
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
25
Loop units | Input and output units
Input and output units
AutroSafe oers a wide range of input and output units for many dierent applications. The system features Exn-, Exia- and Exd approved input and output units for
high risk applications. All input and output units feature automatic addressing and short-circuit protection.
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL2*
Ingress Protection level**
Notes
116-BN-180 AutroKeeper
IP30
Use two units to access
one loop from two loop
controllers.
DIN rail mounting in
cabinet.
116-BN-201 Monitoring unit 1/0
IP54
IP67
For external units
116-BN-221/01
Extinguishing control
unit
2/1 IP67
116-BN-221/02
Output unit with
7 A relay
0/1 IP67 Loop controlled FAD unit
116-BN-300 Input unit 1/0
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 41)
SelfVerify ensures
optimal detection
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
26
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL2*
Ingress Protection level**
Notes
116-BN-300M Modular input unit 1/0 Mounting on TS-35 rail
116-BN-303
Single monitored
input unit
1/0
IP54
IP67
Function selectable
via dip switch
Limited approvals
(Not SIL2/FM/USCG)
116-BN-304 Input/output unit 1/1
IP54
IP67
Function selectable
via dip switch
Limited approvals
(Not SIL2/FM/USCG)
116-BN-305
Dual monitored input/
output unit
2/2
IP54
IP67
Function selectable
via dip switch
Limited approvals (Not
SIL2/FM/USCG)
116-BN-307
Monitored Fire Alarm
Device Control Unit
0/1
IP54
IP67
Limited approvals (Not
SIL2/FM/USCG)
116-BN-310 Relay output unit 0/1
IP54
IP67
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 41)
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
27
Loop units | Input and output units
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL2*
Ingress Protection level**
Notes
116-BN-320 Interface unit 2/1
IP54
IP67
116-BN-320/2 Door control unit 2/1
IP54
IP67
116-BN-320/4 Standard control unit 2/1
IP54
IP67
Control of external
equipment
116-BN-320/5
Sprinkler monitoring
unit
1/0
IP54
IP67
116-BNB-330A
Loop adapter unit for
conventional loops
1/1 IP20
Replacement unit for
BNB-330 in existing
AutroSafe 3 systems
116-BNB-331
Loop adapter unit for
conventional loops
1/1 IP20
AutroSafe ver. 4.4.1
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 41)
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
28
Image Part number Description
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL2*
Ingress Protection level**
Notes
116-BN-500/EX Input unit 1/0
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
Zones 0, 1 & 2
116-BN-500/N Input unit 1/0
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
Zone 2
116-BN-505/EXD
Input unit with BNB-
300
1/0 IP66 Zones 1 & 2 only
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 41)
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
29
Loop units | Control units
Control units
AutroSafe oers control units for enabling and disabling of detectors, as well as daytime/nighttime units. Available in several language versions. Replace
XX with country code.
Image Part number Description
Number of buttons
For external control
Configurable delay
For AutroSafe only
Ingress Protection level
Notes
116-BW-200/XX Disablement unit
2 IP66 Available in Swedish, English and Russian
116-BW-201/XX Disablement unit 0 IP66 Available in Swedish and English
116-BW-202/XX
Daytime/Nighttime
unit
2 IP66
Up to two units can be powered from detector
loop. To connect more units, external 24 VDC
power is required.
Available in English only.
116-BW-203/XX
Daytime/Nighttime
unit
0 IP66
Up to two units can be powered from detector
loop. To connect more units, external 24 VDC
power is required.
Available in English only.
116-BU-200 Alarm controller unit 2 IP66
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
30
Detectors
AutroSafe oers a wide range of detectors for many dierent applications, with or without SelfVerify. The following series are available:
200 series, standard interactive addressable detectors
300 series with SelfVerify, interactive addressable detectors
500 series with SelfVerify, interactive addressable detectors for use in hazardous areas
The system also oers Exn- and Exia approved versions of detectors designed for use in high risk applications. S series smoke detectors are specially
designed for applications where high sensitivity is required.
Image Part number
Heat
Smoke
MultiSensor
SelfVerify
Including base
Environmentally protected
For use in EX areas
For use in EX zone 2 only
High sensitivity
Sealed unit
SIL 2 certified
Ingress Protection level
Notes
116-BD-200M
IP56
For galleys/cold areas
(-30 ºC)
116-BD-501 IP56
116-BD-501/EX IP56
116-BD-501/N IP56
116-BD-55/XXXEXD IP66/67
*
Conventional
116-BD-55/XXXEXDN IP66/67
**
Conventional
116-BD-505/140EXD IP66
60 ºC, non-configurable class,
explosion proof
116-BD-505/160EXD IP66
70 ºC, non-configurable class,
explosion proof
116-BD-505/190EXD IP66
90 ºC, non-configurable class,
explosion proof
116-BDH-300 IP44D
116-BDH-500 IP44D
116-BDH-500/EX IP44D
116-BDH-500/N IP44D
*: Available with the following alarm temperatures (replace XXX with °F): 140 °F (60 °C), 160 °F (70 °C), 190 °F (90 °C), 225 °F (110 °C),
325 °F (165 °C), 360 °F (180 °C), and 450 °F (230 °C)
**: Available with the following alarm temperatures (replace XXX with °F): 225 °F (110 °C), 275 °F (135 °C), 325 °F (165 °C), 360 °F (180 °C),
and 450 °F (230 °C)
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
31
Loop units | Detectors
Image Part number
Heat
Smoke
MultiSensor
SelfVerify
Including base
Environmentally protected
For use in EX areas
For use in EX zone 2 only
High sensitivity
Sealed unit
SIL 2 certified
Ingress Protection level
Notes
116-BHH-300 IP44D
116-BHH-500 IP44D
116-BHH-500/EX IP44D
116-BHH-500/N IP44D
116-BHH-500/S IP44D
116-BHH-500/S/EX IP44D
116-BHH-500/S/N IP44D
116-BHH-320 IP44D
116-BHH-520 IP44D
116-BHH-520/EX IP44D
116-BHH-520/N IP44D
116-5815-021.0001 IP54
Thermostat ATHF-SE-2, 20-150°C
For use in Safe Area or Ex zone 2
Suitable for use in sauna
116-5861-033.0150 IP65 SWM-1KL 140°C
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
32
Manual call points and release stations
AutroSafe oers a wide range of manual call points for dierent applications, every unit features SelfVerify.
Two main series are available:
300 series with SelfVerify, interactive addressable manual call points.
500 series with SelfVerify, interactive addressable manual call points for use in special environments.
The system features Exn- and Exia approved versions for high risk applications.
All our manual call points can be delivered with a double-action cover.
Image Part number Description
For use in EX areas
For use in EX zone 2 only
Watertight / outdoor model
Extreme environments
LED indicator
Metal connection box
Glass NOT included
Optional duty label*
Ingress Protection level
116-BF-300V2 Manual call point
IP42D**
116-BF-510WP-H Manual call point IP52**
116-BF-500V2/EX Manual call point IP44D**
116-BF-500V2/N Manual call point IP44D**
116-BF-501 Manual call point IP66
116-BF-501/EX Manual call point IP66
116-BF-501/N Manual call point IP66
*: See “Duty lables” on page 34
**: Ingress Protection level inner housing
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
33
Loop units | Manual call points and release stations
Image Part number Description
For use in EX areas
For use in EX zone 2 only
Watertight / outdoor model
Extreme environments
LED indicator
Metal connection box
Glass NOT included
Optional duty label*
Ingress Protection level
116-BF-502 Manual call point IP66
116-BF-502/EX Manual call point IP66
116-BF-502/N Manual call point IP66
116-BF-503/100 Manual call point N/A IP66
116-BF-503/EX/0100 Manual call point N/A IP66
116-BF-503/N/0100 Manual call point N/A IP66
116-KIT-BF-503/EX/0300 Release station N/A IP66
116-KIT-BF-503/N/0300 Release station N/A IP66
116-KIT-BF-503/0400 Release station N/A IP66
116-KIT-BF-503/EX/0400 Release station N/A IP66
116-KIT-BF-503/N/0400 Release station N/A IP66
116-KIT-BF-503/0500 Release station N/A IP66
116-KIT-BF-503/EX/0500 Release station N/A IP66
116-KIT-BF-503/N/0500 Release station N/A IP66
116-BFG-3/XX
Glass for call point, available in several languages. Replace XX with country code.
No ending = No text
GB = English
GB/AR = English and Arabic
N/GB = Norwegian and English
SU = Russian
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
34
Duty lables
Part number Text Part number Text
116-E-2327/1 Inergen utløsning | Inergen Release 116-E-2327/26 CO2 Release station
116-E-2327/2 Brannmelder | Fire alarm 116-E-2327/27 CO2 Inhibit station
116-E-2327/3 Water release 116-E-2773/1 Abandon ship
116-E-2327/4 Fire | Brann 116-E-2773/2 Abandon
116-E-2327/5 Vannutløsning | Water release 116-E-2773/3 Gass | Gas
116-E-2327/6 Inergen press. | Release 116-E-2773/4 Vanntåke
116-E-2327/7 Vannutløser | Water release 116-E-2773/5 ESD 2
116-E-2327/8 Fire Monitor | Water release 116-E-2773/6 CO2 release & inhibit station
116-E-2327/9 Deluge | Water release 116-E-2773/7 VEEUDU KÄIVITAMINE
116-E-2327/10 Deluge release 116-E-2773/8 Argonite
116-E-2327/11 Vanntåke | Water mist 116-E-2773/9 General emergency alarm
116-E-2327/12 Alarm 116-E-2773/10 Argonite Release
116-E-2327/13 Overrisling | Deluge 116-E-2773/11 ESD
116-E-2327/14 Start fire pumps | Старт пожарный насос 116-E-2773/12 Electrical isolation
116-E-2327/15 Vanntåke | Utløsning 116-E-2773/13 MCP | Ручной извещатель
116-E-2327/16 Overrisling 116-E-2773/14 ESD AB. OCT.
116-E-2327/17 Fire Push button 116-E-2773/15 CO2 Manual station abort
116-E-2327/18 General Alarm 116-E-2773/16 CO2 Manual station release
116-E-2327/19 FM200 release 116-E-2773/17 Manual alarm call point
116-E-2327/20 FM200 inhibit 116-E-2773/18 Exstinguishant release pushbutton
116-E-2327/21 Fire 116-E-2773/19 East monitor actuation
116-E-2327/22 Water mist release 116-E-2773/20 West monitor actuation
116-E-2327/23 Start Firewater pump 116-E-2773/21 Foam system release
116-E-2327/24 Start Foam skid 116-E-2773/22 Vannutløser | Deluge release
116-E-2327/25 Clean Agent release
MEDC manual call points and release stations
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request.
These products are produced according to customer specifications.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
35
Loop units | Alarm units
Alarm units
AutroSafe oers a wide range of alarm units for connection to detection loops or dedicated alarm outputs.
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output
Candela (c), Joule (j)
Ingress Protection level
Notes
116-BBL-100
Alarm indicator - 2 c IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBL-100/IP Alarm indicator - 2 c IP66
Supported only
by AutroSafe
version 4.3 or
later
116-BBR-7M Alarm bell 6” 93 IP55
116-BBR-130
Combined
detector base
and addressable
sounder.
90 IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBR-230 Sounder 100 IP32C
Supported only
by AutroSafe
version 4.3 or
later
*: If loop driver BSD-311 is used, max. no. of units per loop is 40
If loop driver BSD-310 is used, max. no. of units per loop is 21
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
36
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output
Candela (c), Joule (j)
Ingress Protection level
Notes
116-BBR-230/IP Sounder 100 IP65
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-130
Base sounder w/
alarm indicator
90 2 c IP21C
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-230
Sounder/alarm
indicator
100 2 c IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-230/IP
Sounder/alarm
indicator
100 2 c IP65
Supported only
by AutroSafe
version 4.3 or
later
116-BU-47
Conventional
alarm indicator
IP30
116-7770-009.0002
Roshni LP, shallow
base
10-
112
IP54
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
37
Loop units | Alarm units
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output
Candela (c), Joule (j)
Ingress Protection level
Notes
116-7770-009.0004
Roshni LP, shallow
base
102 IP54
116-7770-009.0005 Roshni, deep base 102 IP65
116-7780-004.0001
Flashni, shallow
base
101 0,7 j IP54
116-7780-004.0002 Flashni, deep base 101 0,7 j IP65
116-7782-001.0003 Sounder 110
IP66
/67
48 VDC
ATEX approval
Ex II 2GD
EExd IIC T5
116-4340-006.0201 Xenon beacon 5 j
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
38
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output
Candela (c), Joule (j)
Ingress Protection level
Notes
116-4340-006.0924
Solex beacon,
shallow base
2,5 c IP54
116-4340-006.0925
Solex beacon,
deep base
2,5 c IP65
116-4340-006.0926
Solex beacon,
shallow base
2,5 c IP54
116-4340-007.0001
Solista LX beacon,
wall mounted ,
deep base
W-
2.4-
7.5
IP65 Red flash
116-4340-007.0002
Solista LX beacon,
ceiling mounted,
shallow base
C-3-
7.5
IP33C Red flash
116-4340-007.0005
Symphoni LX
WP conventional
base beacon, wall
mounted
W-
2.4-
7.5
IP66 Red flash
116-7770-009.0040 Symphoni IP66 100 - IP66
For use with 116-
4340-007.0005
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
39
Loop units | Alarm units
Image Part number Description
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output
Candela (c), Joule (j)
Ingress Protection level
Notes
116-4340-007.0007
Solista LX wall,
shallow base
C-3-
7.5
IP33C Red flash
116-4340-007.0008
Symphony G1 LX,
wall
100
W-
2.4-
7.5
IP21C Red flash
116-4340-007.0009
Symphony G1 LX,
wall
100
W-
2.4-
7.5
IP21C Red flash
MEDC beacons, sounders, and combination units
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request.
These products are produced according to customer specifications.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
40
Door magnet
Image Part number Description
116-6731-017.0002
Door magnet armature. Type AG w/adjustable socket.
For use with part no: 116-6731-017.0005
116-6731-017.0005
Door holding magnet. GPT, holdpower 650 N, 1 W, 40 mA.
Manual release push button. DNV approved.
For use with part no: 116-6731-017.0002
Accessories for loop units
Image Part number Description
Suitable for EX
installations
116-BWA-100 Base for interactive detector heads, mandatory
116-BWB-110
Base adapter for analogue addressable detectors mounted on interactive
loops
116-BWP-100/20 Drip proof conduit box with M20 glands
116-BWP-100/25 Drip proof conduit box with holes for M25 glands
116-BWP-143A Ventilation duct adapter for smoke detectors, for interactive systems
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
41
Loop units | Service tools for detection loops
Image Part number Description
Suitable for EX
installations
116-BWP-143A-SS
Ventilation duct adapter for smoke detectors, for interactive systems.
Stainless steel version for use in harsh environmental conditions, oshore
and onshore.
116-BJ-358/100 Pipe kit, L=100 mm
116-BJ-358/150 Pipe kit, L=150 mm
116-BJ-358/300 Pipe kit, L=300 mm
116-BJ-358/550 Pipe kit, L=550 mm
116-BJ-358/800 Pipe kit, L=800 mm
116-BJ-358/1000 Pipe kit, L=1000 mm
116-BWP-145 Heated detector base
116-8142-983.5115 Transformer 230/48 V for up to 10 BWP-45/BWP-145
116-WBW-100 Bypass unit for BWA-100
116-WBW-101 Mounting plate for false ceilings
116-BZ-500 Galvanic barrier for Exia approved detectors, for field mounting
116-BZ-500/01 Galvanic barrier for Exia approved detectors, for cabinet mounting
116-UL-050 Robust bracket for manual call points
116-4860-011.0100 Polycarbonate cover for manual call point BF-300V2
116-4890-021.0001 Lift flap in polycarbonate for manual call point 116-BF-502, all versions
116-4890-021.0010 Lift flap in stainless steel for manual call point 116-BF-502, all versions
116-4890-022.0001 Lift flap in polycarbonate for manual call point 116-BF-501, all versions
116-4890-022.0010 Lift flap in stainless steel for manual call point 116-BF-501, all versions
116-6571-011.1920
Cable gland M20-1.5 for Ingress Protection level IP67 for I/O units.
NB! Order with 116-6531-006.1920
116-6531-006.1920 Backnut for cable gland IP67. NB! Order with 116-6571-011.1920
116-7770-009.0008 Power base 230 V for Roshni alarm unit
116-4890-022.0010 Lift flap in stainless steel for manual call point 116-BF-501, all versions
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
42
Service tools for detection loops
Image Part number Description
Suitable for EX
installations
116-WAS-2000 AS2000, loop diagnostic tool in casing, including PC cable
116-WBJ-5/01 Test gas dispenser for smoke detectors, excluding pole
116-WBJ-5/02 Telescopic pole, 1,26 m to 4,5 m, 1,8 kg
116-WBJ-5/03 Expansion pole, 1,13 m. 0,5 kg
116-WBJ-5/04 Test gas for smoke detectors
116-WBJ-6/01
Heat detector test kit, battery operated, 2 x batteries and charger included
(for WBJ-5/02)
116-WBJ-10
Testifire smoke/heat detector test kit (head unit 2 x battery baton and fast
charger)
116-WBJ-10/01 Testifire smoke/heat head unit
116-WBJ-10/02 Smoke capsule for WBJ-10 (6 pack)
116-WBJ-10/03 Solo 760 battery baton
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
43
Loop units | Service tools for detection loops
Image Part number Description
Suitable for EX
installations
116-WBJ-10/04 Solo 725 universal fast battery charger
116-WBJ-140 Installation/extraction tool for AutroSafe detectors
116-7870-004.0012 Timer for use with disablement unit BW-201, 2POL/16A 12 hours
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
44
Protecting life, environment and
property, by any means necessary
Autronica’s flame detectors are solutions for applications in which risk to
personnel is high and where fire might result in a large loss of equipment.
Beyond critical life-safety concerns, our products have proven to minimize
total cost of ownership while minimizing false alarms.
Our industrial and commercial applications include oil and gas pipelines,
turbine enclosures, oshore platforms, and Floating Production Storage
and Ooading (FPSO) vessels.
Bottom line – no other company oers more flame-detection technologies
with wider area coverage, higher false-alarm immunity, reduced response
times, and the appropriate global approvals. And to improve ease of use, all
X-Series flame detectors have HART-protocol options.
Flame detection
Keeping a close watch
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
45
Flame detection | Flame detectors
Flame detectors
All flame detectors have 4 x M25 cable entries, unless otherwise specified. Swivel mount, glands and blind plugs are not included.
All detectors have an ambient temperature range of -55°C to + 60°C for T6 and -55°C to + 75°C for T5, unless otherwise specified.
Ingress Protection level all detectors and cameras: IP66
Image Part number Description
Stainless steel housing
Aluminium housing
Addressable (built-in BNB-300)
Combination unit with camera av.
For PowerLoop
Cert. -55 °C to +125 °C for T4
With HART protocol
SIL 2 approved
Notes
116-5861-011.4310 AutroFlame X33AF multisp. IR
116-5861-011.4320 AutroFlame X33AF multisp. IR
116-5861-011.4341 AutroFlame X33AF multisp. IR
116-5861-011.4360 AutroFlame X33AF multisp. IR
116-5861-011.4361 AutroFlame X33AF multisp. IR
116-5861-011.4373 AutroFlame X33AF multisp. IR
116-5861-011.4385 AutroFlame X33AF multisp. IR
116-5861-011.4392 AutroFlame X33AF multisp. IR
UL Brazil approved
3/4” NPT
116-5861-011.4393 AutroFlame X33AF multisp. IR
116-5861-011.4410 AutroFlame X33AF PL multisp. IR
116-5861-011.4411 AutroFlame X33AF PL multisp. IR 3/4” NPT
116-5861-011.4420 AutroFlame X33AF PL multisp. IR
116-5861-011.4440 AutroFlame X33AF PL multisp. IR
116-009009-002 AutroFlame X32AF multisp. IR
Hydrogen flame
detection
116-009011-002 AutroFlame X32AF multisp. IR
Hydrogen flame
detection
116-5861-011.3980 AutroFlame X98 single IR
116-5861-011.3981 AutroFlame X98 single IR
116-009585-001 xWatch surveillance camera
For use with any
flame detector above.
M20
PAL video output. For
use in EX areas FM/
CSA approved
768 x 484 px
90° optical lens*
116-009587-001 xWatch surveillance camera
*Other lenses available
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
46
Cable glands/Blind plugs
Part number Description
116-6332-032.1925 Blind plug M25, polyamid, Eexe, Ingress Protection level: IP67
116-6530-030.0020 SPMH/NP/M20 blind plug nickle plated brass
116-6530-030.0025 SPMH/NP/M25 blind plug nickle plated brass
116-6571-016.2520 Cable gland adapter M20/M25
116-6571-018.2025 EEXDE adapter M25-20 nickle plated brass
116-6571-070.2025 Cable gland A2LBFM25NP, Brass - nickel plated, Exd/Exe, Ingress Protection level: IP66/68
116-6571-071.2500 Cable gland M25, polyamid, Eexe, Ingress Protection level: IP67
116-6571-080.0001 501/453/UNIV/B M25 nickle plated brass
116-6571-080.0002 501/421/B M25 EEXE nickle plated brass
116-6571-080.0005 501/453/UNIV/O-M20 nickle plated brass
116-6571-080.0006 501/453/UNIV/A-M20 nickle plated brass
116-6571-080.0007 501/421/Os M20 EEXE nickle plated brass
116-6571-080.0009 501/421/A M20 EEXE nickle plated brass
Accessories
Part number Description
116-001680-001 K1003A1006 Window cleaner for flame detectors (6 pcs.)
116-004404-002 Q9001H8001 swivel for xWatch camera SS
116-002099-003 Q9001B1175 swivel for xWatch camera alu.
116-5861-011.9050 Q9033B Swivel mount for AutroFlame detectors, stainless steel
116-5861-011.9051 Q9033A Swivel mount for AutroFlame detectors, aluminium
116-007338-010 Q2033A10R 10 degree field-of-view limiter
116-007338-020 Q2033A20R 20 degree field-of-view limiter
116-007338-030 Q2033A30R 30 degree field-of-view limiter/Weather shield (maintains standard field-of-view)
116-007240-001 Q1116A air shield assembly
116-009199-001 Q1198A dual air shield/flange mount assembly
116-102740-002 Calibration magnet for X series flame detectors
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
47
Flame detection | Test equipment
Test equipment
Part number Description
116-006439-004 W8067S Long range test lamp IR/UVIR, (non-EX). 110VAC charger included.
116-004000-006 W867C Portable test lamp 220 V, UV, UV/IR & Single IR
116-007255-001 Q1201C Laser holder for AutroFlame X33AF, UV/IR and UV flame detectors
116-006097-001 Laser aimer (non-EX) for AutroFlame detectors incl. battery
116-009997-001 Universal Battery Charger for W867 and W8067, 110/220 VAC
116-007819-001
W6300B Inspector connector for connection to PC utilizing an integral RS485 to RS232 converter
for communication
116-009207-001 Inspector monitor software. To be used together with inspector connector
116-009208-001 O/I replacement kit for AutroFlame X33AF with black reflector plate*
116-010831-001 O/I replacement kit for AutroFlame X33AF with stainless steel reflector plate*
116-009208-002 O/I replacement kit for AutroFlame X22, X52 and X98
116-007739-001 Test magnet and extension pole
*: Please note: AutroFlame X33AF models are supplied with either a black or a stainless steel reflector plate. These plates are not interchangeable. Order the
replacement that matches the reflector plate on your AutroFlame X33AF detector.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
48
When it comes to detecting toxic gas would you rather be alerted in 30
seconds... or 5 seconds?
In the demanding environments of the petrochemical oil and gas industry,
fire and gas detection has to deliver optimal results at all times. Autronica
oers traditional detectors with 4-20 mA and/or relay output, but we have
also taken the IR point gas detection a step further. By introducing the
two wire intelligent communication on our IFG PowerLoop we allow for
centralized control of all diagnostic data. Analogue readings and detector
self testing features are available from our AutroPoint IR gas detectors.
The line-of-sight IR gas sensing technology surpasses other alternatives,
both with respect to the life cycle cost as well as operational tangibles of
a more technical nature. Our AutroPath HC800 open path infrared beam
system delivers reliable, combustible gas monitoring for all types of
applications.
The AutroSonic Acoustic Gas Leak Detector hears gas leaks that others
don’t – the instant they occur. It is the first non-contact gas leak detector of
its kind that recognizes unique sound “fingerprints,” analyzing 24 discrete
ultrasonic bands, while ignoring nuisance ultrasonic sources. A high-
fidelity microphone continuously monitors for the distinct ultrasound
emitted by pressurized gas leaks across the widest spectrum of frequencies.
With our AutroTox toxic gas detector family, you get a gas detector that
continuously monitors the atmosphere for potentially hazardous gas leaks
and oxygen depletion. An array of sensor models detect a variety of gases
in various concentration ranges.
Autronica delivers the performance, quality, and reliability you can depend
on to keep you safe and satisfied.
Gas detection
When every second counts
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
49
Gas detection | Infrared hydrocarbon gas detectors
Infrared hydrocarbon gas detectors
All units have 4-20 mA with HART protocol and are delivered in stainless steel housing.
Other detectors are available on request
Image Part number Description
SIL 2 approved
HART connector
Hydrophobic filter*
Relay output
Cable
entries
EX
approval Notes
116-010195-232
AutroPoint HC200
2 x M25 Ex d e
116-5861-011.5100 2 x M25 Ex d e
116-010195-233 2 x M25 Ex d
116-007168-233 2 x M25 Ex d
116-010195-234 2 x M25 Ex d e
116-007168-234 2 x M25 Ex d e
116-010195-235 2 x M25 Ex d
116-007168-235 2 x M25 Ex d
116-010195-236 2 x 3/4” NPT Ex d Inmetro
116-010195-237 2 x 3/4” NPT Ex d Inmetro
116-007168-252 2 x 3/4” NPT Ex d e
116-5861-011.5300
AutroPoint
HC300PL
2 x M25
Ex d e
Addressable,
PowerLoop version
116-010195-030 2 × M25
116-010195-036 2 × M25
116-010195-031 2 × ¾’’ NPT
116-010195-037 2 × ¾’’ NPT
116-5861-011.5310 2 × ¾’’ NPT
116-013800-503
AutroPath HC800
M25 Ex d e
5-60 m range
Atex/IECEX
116-013800-553
30-120 m range
Atex/IECEX
116-013801-503
Transmitter spare
Atex/IECEX
116-013802-503
Reciever spare 5-60 m
Atex/IECEX
116-013802-553
Reciever spare 30-120 m
Atex/IECEX
116-013803-503
Transmitter front module
ATEX/IECEX
116-013804-503
Receiver front module
5-60 m
ATEX/IECEX
116-013804-553
Receiver front module
30-120 m
ATEX/IECEX
*: Recommended for areas with high levels of airborne particulates or humidity.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
50
Image Part number Description
SIL 2 approved
HART connector
Hydrophobic filter*
Relay output
Cable
entries
EX
approval Notes
116-GD10-P00-17DG-
0XH-00
GD-10P 2xM20 Ex d e 1 sec. response
116-Z-02104N4011
Searchline Excel IR
gas detector
116-Z-02104NXSSA
With SNX universal
transmitter
Acoustic gas detectors
All units have 4-20 ma with HART protocol and are delivered in stainless steel housing.
Image Part number Description
SIL 2 approved
HART connector
Cable
entries EX approval Notes
116-012152-001
AutroSonic acoustic
gas detector kit
3/4” NPT
Ex d
FM/CSA/ATEX/IECEX
approved.
Kit includes individually
packaged sensor and
transmitter.
116-012153-001 M25
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
51
Gas detection | Toxic gas detectors
Toxic gas detectors
Autronica provides toxic gas detectors for a wide range of gases. These detectors must be combined with a toxic gas sensor module, listed below. All
display units are Ex d approved, having 4-20 mA output with HART and RS-485 in addition to relay outputs.
Image Part number Description
Electrochemical
Stainless steel housing
Aluminium housing
Notes
116-5861-011.6601
AutroTox ATD w/AutroVu AV10 display unit
SIL 2 approved
116-5861-011.6603
Toxic gas sensor modules
Image Part number Description Range
Used with Omicron
point gas detection system
OGS 2.1 (
Used with Omicron
gas sampling system
OGS 3.1 (page 69)
SIL 2 capable
116-009471-001 GTS H
2
S 20P 0 – 20 ppm
116-009471-002 GTS H
2
S 50P 0 – 50 ppm
116-009471-003 GTS H
2
S 100P 0 – 100 ppm
116-009471-004 GTS Cl
2
10P 0 – 10 ppm
116-009471-006 GTS NH
3
500P 0 – 500 ppm
116-009471-008 GTS H
2
1000P 0 – 1000 ppm
116-009471-009 GTS O
2
25V 0 – 25 % by volume
116-009471-010 GTS CO 100P 0 – 100 ppm
116-009471-011 GTS CO 500P 0 – 500 ppm
116-009471-503 GTS H
2
S 100PTD, DNV approved 0 – 100 ppm
116-009471-509 GTS O
2
25VTD, DNV approved 0 – 25 % by volume
116-009471-510 GTS CO 100PWD, DNV approved 0 – 100 ppm
116-009471-511 GTS CO 500PWD, DNV approved 0 – 500 ppm
116-009471-532 GTS H
2
S 50P, DNV approved 0 – 50 ppm
INMETRO approved versions available
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
52
Display units
All display units are Ex d approved, with 4-20 mA output with HART and RS-485 in addition to relay outputs.
Image Part number Description
Electrochemical
Catalytic combustible
Stainless steel housing
Aluminium housing
SIL 2 approval
Cable entries
Notes
116-011780-001 AutroVu AV10
5xM25
116-011780-002 AutroVu AV10 5xM25
116-011780-006 AutroVu AV10 3/4 NPT
116-011780-081 AutroVu AV10 3/4 NPT INMETRO (Brazil)
116-011780-082 AutroVu AV10 3/4 NPT INMETRO (Brazil)
116-011780-003 AutroVu AV10 CGS 5xM25
116-011780-004 AutroVu AV10 CGS 5xM25
Toxic gas transmitters and termination boxes
Image Part number Description
Electrochemical
Stainless steel housing
Aluminium housing
Eex d certified
Notes
116-009480-004 GTX Transmitter
Used with Omicron point gas detection
system OGS 2.1 (page 67) and OGS 3.1
(page 69)
116-226365-603 STB Termination Box For GT3000, M25, SS, 5 ports
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
53
Gas detection | Accessories
Accessories
Part number Description
116-007525-003 Direct duct mount kit for point gas detectors AutroPoint HC200
and
HC300PL
116-009700-001 Magnetic tool for AutroSonic acoustic detector and AutroVu display
116-012513-001 Q912 Duct mount M25 with 1 ft. inlet
116-012513-003 Q912 Duct mount M25 with 3 ft. inlet
116-012513-006 Q912 Duct mount M25 with 3 ft. inlet
116-012513-010 Q912 Duct mount M25 with 10 ft. inlet
116-012513-013 Q912 Duct mount M25 with 13 ft. inlet
116-012673-001 System test film for AutroPath HC800, set of 5 films
116-012287-002 Alignment telescope for AutroPath HC800
116-226365-127 Toxic sensor termination box and separation kit. JBOX, SEP, AL, M25 CENELEC Infinity
116-US-843 Rain and sun shield for point gas detectors AutroPoint HC200
and
HC300PL
116-Z-475HP1EKL9GMT
Emerson 475 HART communicator. Instrument for calibration of AutroPoint HC200 and
AutroPath HC600 gas detectors. Certified intrinsically safe by CENELEC/ATEX, FM, CSA, FISCO and IECEx
116-Z-GD10-ADAPT1 Duct adapter for point gas detector GD-10P
116-Z-499815712 Sunshade, GD10/PGD10PE
For cable glands and blind plugs, see flame detector section, page 45.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
54
Calibration kits
Part number Gas type Concentration Notes
116-006468-001 Methane CH
4
50 % LEL AutroPoint HC200/-300
116-007098-005 Hydrogen Sulphide H
2
S 50 ppm 12 x ampoules, NTMOS detectors
116-010274-001
Hydrogen Sulphide H
2
S 10 ppm GT3000 series
116-010274-002
Hydrogen Sulphide H
2
S
25 ppm
GT3000 series
116-010274-004
Chlorine Cl
2
5 ppm GT3000 series
116-010274-005
Ammonia NH
3
50 ppm GT3000 series
116-010274-006
Ammonia NH
3
250 ppm GT3000 series
116-010274-008
Hydrogen H
2
500 ppm GT3000 series
116-010274-009
Oxygen O
2
20,90 % GT3000 series
116-010274-010
Carbon Monoxide CO 50 ppm GT3000 series
116-010274-011
Carbon Monoxide CO 250 ppm GT3000 series
116-010274-013
Sulfur Dioxide SO
2
10 ppm GT3000 series
116-010274-014
Sulfur Dioxide SO
2
50 ppm GT3000 series
116-225130-005 Hydrogen H
2
50 % LEL AutroPoint H
2
116-225130-009 Without gas
AutroPoint H
2
Accessories for calibration kits
Part number Description
116-004976-001 Calibration cup for catalytic detectors, stainless steel
116-005964-001 Calibration cup for point gas detectors AutroPoint H
2
S, O2 and TX50
116-225741-001 Extra ampoules for 116-007098-005 NTMOS Calibration Kit H
2
S Ampoule, 50 ppm
116-227117-001 GT3000 replacement cylinder H2S 50 ppm
116-227117-006 GT3000 replacement cylinder O2 20,90%
116-227117-012 GT3000 replacement cylinder H2S 25 ppm
116-227117-018 GT3000 replacement cylinder H2 500 ppm
116-Z-00670 Step regulator with 0,5 L constant flow
116-Z-00671 Step regulator with 1 L constant flow
116-Z-00678 Carrying case for 2 bottles
116-Z-1200674 2.5 LPM constant flow regulator
116-Z-1711020 Test gas, 65 % LEL methane in N2. 110 L
116-Z-1501020 Test gas, 50 ppm H
2
S. 110 L
116-Z-1404010 Test gas, 50 % LEL H
2
. 110 L
116-Z-499810874.8 Sample Flow Housing for point gas detector GD-10P
116-Z-1200673 Reg. valve 0.3-3.0 L/min
Other concentrations and test gases available on request.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
55
Gas detection | Calibration kits
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
56
Other detectors
– completing the fire detection system
Alarmline linear heat detection (LHD) is a cable-based system providing
economical temperature monitoring at the precise point of risk.
The system is reliable, flexible and has the ability to detect abnormal
temperature variances before fire breaks out. The comprehensive LHD
product portfolio allows a vast range of commercial and industrial fire and
overheat risks to be protected, in ambient temperatures of 68°C to 185°C.
Other options/alarm temperatures available on request.
Aspirating detectors function by sampling air via a network of pipes,
sampled air is passed through a dust filter and into a detector chamber
where the air is analyzed for traces of smoke. Typical applications include
laboratories, large open spaces, corrosive environments, archives/
historical buildings and industrial areas. Every detector is “trainable” for
the specific environment in which it is installed.
Common to all AutroSense detectors is that they are capable of detecting
the small amounts of smoke that are generated in the initial phases of a
smouldering fire, ensuring the earliest possible warning of a potential fire.
At the same time, AutroSense detectors distinguish real smoke from dust
and pollutants, reducing unwanted alarms to a minimum.
AutroSense 200, AutroSense Micra 25 and Micra 100 are stand-alone
aspirating detectors, that can also be connected to fire alarm systems.
These units feature built-in intelligence that ensures optimal detection
capability.
Beam detectors are used in large open areas instead of a quantity of point
smoke detectors. The detector protects a given area by sending signals
(infrared light beam) between a transmitter and receiver, and detect
dimmer or changes in frequency by heat or smoke. Beam detectors are
suited to applications in open spaces where costs associated with point
smoke detectors would be prohibitive.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
57
Other detectors | Alarmline linear heat detectors
Alarmline linear heat detectors
Image Part number Description
116-AD68N-0001
Digital cable, 68 °C nylon
116-AD88N-0001 Digital cable, 88 °C nylon
116-AD105N-0001 Digital cable, 105 °C nylon
116-AD185SS-0001 Digital cable, 185°C stainless steel and nylon
116-AAN-0001 Analogue LHD cable, nylon
116-AACUSP Analogue LHD control unit, self programmable
Recommended interface unit for Alarmline linear heat detectors is BN-303 (see page 26)
Accessories
Part number Description
116-5843-005.9002 Alarmline L-bracket
116-5843-005.9003 Alarmline edge clip
116-5843-005.9004 Alarmline T-clip
116-5843-005.9005 Alarmline pipe clip
116-5843-006.0010 Termination kit K82023
116-5843-007.0003 Neoprene sleeve B6782-08
116-5843-007.0004 Cable ties B6782-121
Aspirating detectors
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
58
Image Part number Description
Sensitivity
(obsc./m)
Max. length piping
Max. coverage (FG)
Max. coverage BS6266
(Hot Wire Test)
Sampling pipe inlets
Max. sampling holes
Alarm levels
Relays
116-5861-018.2000 AutroSense 200
0,003–25% 200 m 2000 m² 500 m² 4 100 4 5
116-5861-018.1007 AutroSense Micra 25 0,0015–25% 25 m 450 m² 450 m² 1 10 1 2
116-5861-018.1107 AutroSense Micra 100 0,0015–25% 100 m 1600 m² 500 m² 2 50 1 2
Recommended interface unit for aspirating detectors is BN-303, see “Input and output units” on page 26)
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
59
Other detectors | Accessories
Accessories
Part number Description
116-5861-018.2110
AutroSense command module w/o PSU
116-5861-018.4110 AutroSense Micra relay card w/inputs
116-5861-018.9027 AutroSense 200 dust filter
116-5861-018.9028 AutroSense Micra 25 and 100 dust filter
116-5861-018.3051 Wire burn unit
116-5861-018.9999 Cable for “hot wire” test (roll @ 100 m)
116-5861-018.3422 AutroSense air heater
116-XJA-030 Programming cable for AutroSense Micra
116-BW-75/04 Condensation bottle
116-BW-75/06 Filter
116-BWP-144 AutroSense, detector housing for sampling pipes with detector base BWA-100
116-5861-966.0009 Smoke pellets
116-5861-966.0010 Smoke matches
Piping – halogen free
Image Part number Description Thickness Colour
116-5862-001.0025
Water hose in coil, 25 mm PE50 NT10.
Please specify desired length: 50 or 300 meters
25 mm
116-5861-910.0027
Straight pipe L = 3 m
27 mm / 3/4” Red
116-5861-999.0027 27 mm / 3/4” Grey
116-5861-999.0025 25 mm Red
116-5861-999.0025W 25 mm White
116-5861-999.0025G 25 mm Grey
116-5861-914.1027
Joining socket
27 mm / 3/4” Red
116-5861-998.027G 27 mm / 3/4” Grey
116-5861-998.0025 25 mm Red
116-5861-998.0025W 25 mm White
116-5861-998.0025G 25 mm Grey
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
60
Image Part number Description Thickness Colour
116-5861-964.0001
T-piece
27 mm / 3/4” Red
116-5861-997.0027G 27 mm / 3/4” Grey
116-5861-997.0025 25 mm Red
116-5861-997.0025W 25 mm White
116-5861-997.0025G 25 mm Grey
116-5861-915.1027
Socket union
27 mm / 3/4” Red
116-5861-996.0027G 27 mm / 3/4” Grey
116-5861-996.0025 25 mm Red
116-5861-996.0025W 25 mm White
116-5861-996.0025G 25 mm Grey
116-5861-962.0001
Normal bend 45°
27 mm / 3/4” Red
116-5861-995.0027 27 mm / 3/4” Grey
116-5861-995.0025 25 mm Red
116-5861-995.0025W 25 mm White
116-5861-995.0025G 25 mm Grey
116-5861-912.0027
Normal bend 90°
27 mm / 3/4” Red
116-5861-994.0027G 27 mm / 3/4” Grey
116-5861-994.0025 25 mm Red
116-5861-994.0025W 25 mm White
116-5861-994.0025G 25 mm Grey
116-5861-993.0027G
90° elbow
27 mm / 3/4” Grey
116-5861-993.0025 25 mm Red
116-5861-993.0025W 25 mm White
116-5861-993.0025G 25 mm Grey
116-5861-964.0002
End cap
27 mm / 3/4” Red
116-5861-992.0027G 27 mm / 3/4” Grey
116-5861-992.0025 25 mm Red
116-5861-992.0025W 25 mm White
116-5861-992.0025G 25 mm Grey
116-5861-991.2725
Adapter 27 mm - 25 mm, female/female
Red
116-5861-991.2725W White
116-5861-991.2725G Grey
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
61
Other detectors | Piping – halogen free
Image Part number Description Thickness Colour
116-5861-965.0001 Adapter 27 mm - 25 mm, female/male Red
116-5861-964.0008 Adapter 25 mm -27 mm, female/male Red
116-5861-922.0004
T piece for capillary
27 mm / 3/4” Red
116-5861-989.2510 25 mm Red
116-5861-989.2510W 25 mm White
116-5861-964.0004 Plane test point with 10 mm adapter, 90° 10 mm White
116-5861-922.0007 Discreet capillary sampling point 10 mm Transparent
116-5861-910.0078
Capillary tube
10 mm Red
116-5861-988.0010N 10 mm Transparent
116-5861-018.9021
Capillary sampling point kit flush
27 mm / 3/4” / 10 mm Red
116-5861-987.0025 25 mm / 10 mm Red
116-5861-987.0025N 25 mm / 10 mm Transparent
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
62
Image Part number Description Thickness Colour
116-5861-935.0002 Solvent cement 250 ml w/brush
116-5861-922.0001 Test point, plane shape
116-5861-922.0010 Sampling hole warning labels, 100 psc Red
116-5861-964.0006
Pipe clip
Red
116-5861-986.2527W White
116-5861-986.2527G Grey
116-5861-966.0011
M6-mutter til klips (for å feste klips på M6
«Stand o»)
Transparent
116-5861-966.0001
Compression adapter
27 mm / 3/4” / 10 mm Red
116-5861-985.2510 25 mm / 10 mm Red
116-5861-966.0002
Compression adapter T
27 mm / 3/4” / 10 mm Red
116-5861-984.2510 25 mm / 10 mm Red
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
63
Other detectors | Beam detectors
Image Part number Description Thickness Colour
116-5861-966.0003
ABS test point
27 mm / 3/4” Red
116-5861-983.0025 25 mm Red
116-5861-983.0025W 25 mm White
116-5861-966.0004
Glass condensation trap
27 mm / 3/4” Red
116-5861-982.0025 25 mm Red
116-5861-982.0025W 25 mm White
116-5861-966.0005
Flexible connector 30 cm
27 mm / 3/4” Red
116-5861-981.2530 25 mm Red
116-5861-981.2530W 25 mm White
116-5861-966.0006
Flexible connector 100 cm
27 mm / 3/4” Red
116-5861-981.25100 25 mm Red
116-5861-981.25100W 25 mm White
116-5861-966.0007 Condensation trap with valve 27 mm / 3/4” Red
116-5861-966.0008 Self bilging condesation trap 27 mm / 3/4” Red
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
64
Beam detectors
Image Part number Description
Detection
distance
Ingress
Protection
level Notes
116-5861-023.5101
FireRay 5000-101
Auto aligning infrared optical beam smoke
detector. Transmitter/receiver in the same
housing, plus reflector.
5 – 50 m
IP54
116-5861-023.5102
FireRay 5000-102
Auto aligning infrared optical beam smoke
detector. Transmitter/receiver in the same
housing, plus reflector.
50 – 100 m IP54
116-5861-023.3000
FireRay 3000-101
End to end infrared optical beam smoke detector
system. Transmitter, receiver and compact low-
level controller.
5 – 120 m IP54
Recommended interface units for FireRay detectors are BN-305 (see page 26)
Accessories
Image Part number Description
116-5861-023.5002 FireRay 5000-002: For 50 m – detector head and 1 x reflector
116-5861-023.5039 FireRay 5000-03: For 100 m – detector head and 4 x reflector
116-5861-023.5003 FireRay 5000-003: System controller
116-5861-023.5005
FireRay 5000-005Universal bracket for use with FireRay 5000 detector head or reflector mounting
plate
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
65
Other detectors | Accessories
Image Part number Description
116-5861-023.5006 FireRay 5000-006: Surface mounting plate for 1 or 4 reflectors
116-5861-023.5007
FireRay 5000-007: Mounting plate for 4 reflectors for use with bracket FireRay 5000-005
Image shows plate mounted on bracket, with reflector
116-5861-023.5009
FireRay 5000-008: Mounting plate for 1 reflector for use with bracket FireRay 5000-005
Image shows plate mounted on bracket, with reflector
116-5861-023.5008 Obscuration test filter
116-5861-023.5004 50-100 m kit for FireRay 5000, consisting of 3 reflectors. Included in FireRay 5000-102
116-5861-023.1018 Protection cage for FireRay 5000
116-5861-023.3001 FireRay 3000-015: Pair of detectors (transmitter and receiver) for use with FireRay 3000 system
116-5861-023.3002 FireRay 3000-201: Adjustment bracket for use with FireRay detectors
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
66
Every day, thousands of vessels and oshore production facilities navigate
the world’s oceans, containing valuable and often high-risk products. We
are dedicated to the crew onboard, always doing our best to ensure that
they have the safest working conditions possible.
Each application is unique in design or task, and it is our mission to provide
each one with an optimal safety system. Autronica’s Omicron product
range is designed to meet the most demanding requirements within the
oshore industry. For more than 25 years we have designed gas detection
systems to meet and exceed the individual demands of each installation.
The entire value chain, from project engineering via production to after
sales and administration, is bundled in our Special Detection Competence
Center in Norway, ensuring fast, ecient and high quality project
realization. Based on the experience of approximately 200 projects per year
and our thorough application know-how our team of dedicated and highly
specialized employees will always find the ideal solution for your needs.
Since 1989 we have developed and optimized a range of high end systems
that require minimal maintenance, are extremely robust and reliable as
well as easy to operate. Our service-friendly systems fulfill all regulatory
and class societies’ regulations and enable economically viable operations.
Omicron system can be used in various applications like e.g. FPSO, FSRU,
platforms or drilling rigs.
Omicron systems
Solutions you can trust
Premium quality
safety monitoring and
environmental surveillance
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
67
Omicron systems | Point gas detection system – OGS 2.1
Point gas detection system – OGS 2.1
For all high risk areas that require fast and continuous gas detection
Our point gas detection system OGS 2.1 is the ideal solution for environments that require continuous
monitoring for hazardous gases.
Typical higher risk areas that require fixed point gas detection are e.g. pump rooms and engine
rooms. The system can be equipped with an infinite number of sensors and supports various
detection methods such as e.g. electrochemical, catalytical and infrared technology.
The OGS 2.1 system operates on the same platform as our gas sampling family OGS 3, making it
easy combinable and the ideal extension to the OGS sampling systems whenever both solutions
need to be pooled to one economically sound system. The platform flexibility enables us to meet the
individual customer’s needs.
The OGS 2.1 meets the requirement set out by IMO and the dierent classification societies.
Features
Individual readings and alarm LEDs for each individual sensor
Up to 4 adjustable independent alarm set points
Detection of Oxygen, Hydrocarbons and toxic gases
Infrared, catalytical and electrochemical sensors
Continuous system verification
Intuitive operation
Remote alarm unit to display alarms on a second location e.g. ship’s bridge (optional)
Integrated temperature alarm for cargo pump bearings (optional)
Cargo pump emergency shutdown (option)
RS 485/422 Modbus RTU serial line communication (option)
Separated alarm and detector cabinet (optional)
Part number Name Description
116-KIT-K2001 Gas alarm system OGS 2.1
Control cabinet with integrated alarm panel for a fixed gas detection
system with a set number of sensors. Cabinet to be operated in indoor
safe area. Standard Autronica project documentation included.
Number of sensors must be specified when ordering.
OGS 2.1 Gas Sensors & Accessories
Part number Name Description
116-010195-058 AutroPoint HC200 IR Sensor 0 - 100% LEL, 2 x M25 cable entries
116-75777 GT3000 Junction box
116-14382 Cable gland M20 for GT3000 Junction box
116-M2050 Modbus OGS 2.1
For GT3000 toxic gas sensors, see
Accessories” on page 53
“Toxic gas sensor modules” on page 51
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
68
OGS 2.1 classification
Part number Name
116-Classification Classification by class society
OGS 2.1 spare part kit
Part number Name
116-M6170 OGS 2.1 standard spare part kit
116-M6171 OGS 2.1 3 years spare part kit
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
69
Omicron systems | Gas sampling system – OGS 3.1
Gas sampling system – OGS 3.1
For total solutions in gas sampling
The OGS 3 family is our 4th generation gas sampling systems, relied
on by major operators around the world. Built to withstand the
harshest conditions, the Omicron Gas Sampling Systems are the
ideal solution for gas detection in areas where normal installation
of gas sensors is impossible.
The OGS 3.1 is our top of the range gas sampling system and
typically used in the oil and gas oshore industry. The system
contains a monitoring cabinet and a detector cabinet, that both can
be installed in EX areas. The system’s scalability enables us to design
the ideal solution for the individual operational challenges on e.g.
FPSOs, FLNG or drilling rigs. OGS 3.1 meets the requirement set out
by IMO and the dierent classification societies.
Intuitive and ecient
Within standard operation the OGS system runs a fully automated
sampling sequence from the various defined sampling points. The cycle time is minimized by using 2 independent vacuum pumps; one main pump
that continuously draws air from all sample points and one smaller pump taking samples from the actual point according to the sample sequence. This
ensures fresh samples and a quick response in case gas is detected. The system continuously self verifies all pneumatic components to ensure proper
operation at all times. All alarms, gas as well as potential malfunctions, are shown on the standardized Omicron operator panel in plain text, making the
operation extremely intuitive and limiting training requirements, especially for combined systems.
Scalability
The wide range of optional features in conjunction with the overall system flexibility allow Omicron Gas Sampling Systems to cover a brought range of
applications, ranging from a system with only a few sample points to a tailor made OGS 3.1 system with a centralized monitoring cabinet and several
detector cabinets, making it the ideal solution for large and demanding applications. The system utilize the common Omicron product line platform,
which makes it easily combinable with the Omicron fixed gas detection system OGS 2.1 creating an overall cost eective gas detection solution for an
entire vessel.
Features
Part number Name Description
116-KIT-K3001 OGS 3.1 Alarm & control cabinet
IP66 Control cabinet with integrated alarm panel for a set number of
sample points. Cabinet to be operated in safe area. Standard Autronica
project documentation included.
Number sampling points must be specified when ordering.
116-KIT-K3010 OGS 3.1 Detector cabinet
IP66 detector cabinet for safe area incl. 1 AutroPoint HC200 0-100% LEL
IR sensor, flame arrestors and manifolds for a set number of sample
points. Cabinet to be operated in safe area. Standard Autronica project
documentation included.
Number sampling points must be specified when ordering.
Customer specific configuration and documentation and/or other sensor types on request
Standard
Infrared hydrocarbon sensor(s) with range 0 - 100% LEL
Low and high gas alarms
Flame arrestor and shut o valves for each sampling tube
Automatic and sequential purging of each sampling tube
Two vacuum pumps for reliable detection (main and sample)
Non-return valves to avoid liquid entering into the system
Continuous system verification
Adjustable purge and sample time on every sampling point
Semi-automatic test functionality for span and zero calibration
Manual disconnecting of sampling points that are not in use.
Optional
Multiple gas analysis. Up to 3 dierent gas sensors simultaneously
Dilute functionality for detection of non IR detectable combustible
gases (e.g. NH3)
Repeater display units with control transfer (max. 5)
Remote alarm units with alarm LEDs and sounder (e.g. for bridge)
Bulkhead penetrations
RS 485/422 Modbus RTU serial line communication
Up to 32 freely configurable aux. relay outputs
Dual purge supply (i.e. nitrogen and instrument air)
Standby pump with manual switch over
Eex, Zone 1 design
Special design materials for extreme gases
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
70
OGS 3.1 sensors and system options
Part number Name Description
116-M3252 GT3000 flow cap
116-M3035 Modbus OGS 3
116-M3050 Flamescreen OFS1/10MMOD Flamescreen for exhaust air
116-M3051 FLAMESCREEN OFS1/12mmOD Flamescreen for exhaust air
116-M3078 Shut-o valve 1X6MMOD EX HEX
116-M3079 SShut-o valve 1X6MMOD W/HEX
116-M3080 Shut-o valve 2X8MMOD
116-M3081 Shut-o valve 1X8MMOD
116-M3082 Shut-o valve 2X10MMOD
116-M3083 Shut-o valve 1X10MMOD
116-M3084 Shut-o valve 2X12MMOD
116-M3085 Shut-o valve 1X12MMOD
116-M3140 Filter regulator 12MMOD-12MMTX
116-M3141 Filter regulator 10MMOD-12MMTX
116-M3142 Filter regulator 8MMOD-12MMTX
116-M3060 Bulkhead pen 150/32/ 2X8MM OD
116-M3061 Bulkhead pen 150/32/ 1X8MM OD
116-M3062 Bulkhead pen 150/32/ 2X10MM OD
116-M3063 Bulkhead pen 150/32/ 1X10MM OD
116-M3064 Bulkhead pen 150/32/2X12MMOD
116-M3065 Bulkhead pen 150/32/1X12MMOD
116-M3066 Bulkhead pen 150/22/2X8MMOD
116-M3067 Bulkhead pen 150/22/ 1X8MM OD
116-M3068 Bulkhead pen 150/22/2X10MMOD
116-M3069 Bulkhead pen 150/22/1X10MMOD
116-M3070 Bulkhead pen 150/22/2X12MMOD
116-M3071 Bulkhead pen 150/22/1X12MMOD
116-M3122 Non-return valve 8MM OD SS
116-M3123 Non-return valve 10MM OD SS
116-M3105 Inline filter 90MICRON/8MMOD
116-M3106 Inline filter 90MICRON/10MMOD
116-M3110 Endline filter 8MM OD
116-M3111 Endline filter 10MM OD
116-75321 Water trap
For GT3000 toxic gas sensors, see
Accessories” on page 53
“Toxic gas sensor modules” on page 51
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
71
Omicron systems | Gas sampling system – OGS 3.1
OGS 3.1 spare part kits
Part number Name
116-M6180 OGS3.1 standard spare part kit
116-M6181 OGS3.1 3 years spare part kit
116-M6182 OGS3.1 5 year spare part kit
116-M6183 OGS3.1 standard spare part kit for LPG
116-M6184 OGS3.1 3 years spare part kit for LPG
116-M6185 OGS3.1 5 years spare part kit for LPG
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
72
OGS shale shaker
Gas detection in harsh areas
The OGS Shale Shaker is the newest member of the OGS product family and specially designed to enable reliable gas detection in the harshest oil and gas
environments such as shale shaker ventilation channels or similar areas where traditional gas detectors are quickly contaminated by dirt.
The OGS Shale Shaker is a direct gas sampling system consisting of a zone 1 approved detector cabinet including operation panel and a high end sample
probe. The sample probe provides each sampling point with two sampling tubes. While one tube draws the gas to the sensor, the other one is being
cleaned and vice versa. This provides continuous and reliable detection in the monitored area.
Features
Specially designed for gas detection in shale shaker ventilation
Dual sampling channels enabling reliable detection
Automatic self cleaning routine
IR sensor technology
Continuous system verification
Limited installation costs
High end sample probe competible with standard flange
Sample gas flow alarm
Sample gas inlet temperature up to 70°C
Up to 50m sampling tube
Zone 1 approved
Part number Name Description
116-KIT-K3200 OGS shale shaker standard
Gas sampling system for Shale Shaker applications containing 1
AutroPoint HC 200 IR sensor and standard gas sampling probe.
For use in zone 1, EX d IIB T4.
Standard Autronica project documentation included.
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
73
Omicron systems | OGS direct sampling
OGS direct sampling
Direct gas sampling system for applications where continuous gas monitoring is required but no sensors can be installed due to
the harsh environmental conditions. The system contains 3 AutroPoint HC 200 IR sensors to sample from 3 dierent locations in
parallel and is suitable for use in zone 1, EX 2G IIB T4 Gb.
Standard Autronica project documentation included.
Part number Name Description
116-KIT-K3300 OGS direct sampling system, standard
Pressure based 3 point direct sampling system, 0 - 100% LEL
Tamb 5 - 50°C
116-KIT-K3301 OGS direct sampling system, cold weather
Pressure based 3 point direct sampling system, 0 - 100% LEL
Tamb -25 - 50°C
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
74
Standard accessories
Alarm lights and horns
Part number Name EX approval
Alarm sound
frequency
Alarm
colour
Sound
output
Ingress Protection level
Voltage
116-M6018 Ex d Xenon alarm light BEXBG05 II 2G Ex d IIC T4 Red IP66/67 24 V DC
116-M6019 Ex d Xenon alarm light BEXBG05 II 2G Ex d IIC T4 Amber IP66/67 24 V DC
116-M6020 Ex d Xenon alarm light BEXBG05 II 2G Ex d IIC T4 Blue IP66/67 24 V DC
116-M6021 Ex d Xenon alarm light BEXBG05 II 2G Ex d IIC T4 Red IP66/67 230 V AC
116-M6022 Ex d Xenon alarm light BEXBG05 II 2G Ex d IIC T4 Amber IP66/67 230 V AC
116-M6023 Ex d Xenon alarm light BEXBG05 II 2G Ex d IIC T4 Blue IP66/67 230 V AC
116-M6030 Alarm horn KT75 M20 Air driven 400 Hz 136 dB(A) IP65 24 V DC
116-M6031 Alarm horn KT75 M20 Air driven 800 Hz 136 dB(A) IP65 24 V DC
116-M6034 Alarm horn A121 WR M20 Electrical 1000 Hz 126 dB(A) IP66 24 V DC
116-M6035 Alarm horn A105 WR M20 Electrical 1000 Hz 112 dB(A) IP66 24 V DC
116-M6036 Alarm horn A105 WR M20 Electrical 1000 Hz 112 dB(A) IP66 230 V AC
116-M6037 Alarm horn MA121 WR M20 Electrical 1000 Hz 126 dB(A) IP66/67 24 V DC
116-M6038 EX d Alarm horn II 2G Ex d IIC T4 117 bB(A) IP66/67 24 V DC
116-M6039 EX d Alarm horn II 2G Ex d IIC T4 117 bB(A) IP66/67 230 V AC
116-M6040 EX d Combination Alarm II 2G Ex d IIB T4 Red 117 bB(A) IP66/67 24 V DC
116-M6041 EX d Combination Alarm II 2G Ex d IIB T4 Amber 117 bB(A) IP66/67 24V DC
116-M6042 EX d Combination Alarm II 2G Ex d IIB T4 Red 117 bB(A) IP66/67 230V AC
Test gas
Part number Name Description
116-93019 Hose 6mm PA
116-93626 Quickc male 6mm open/open brass
116-94008 Reduction valve AGA Pressure reducer for test gas w/flowmeter (0-800 ml/min )
116-81029 Methane 50% LEL air 1l/12bar
116-81028 Propane 50% LEL air 1l/12bar
116-96630 N-Butane 50% LEL air 1l/12bar
116-81031 H2S 25 ppm N2 1l/12bar
116-96635 Nitrogen 1l/12bar
116-81024 Test gas. N-Butane 50% L.E.L. in air 10L
116-94009 Flow regulator for AGA 5L 10/l fixicontrol cylinder
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
75
Omicron systems | Standard accessories
Autronica Fire and Security AS, Petrochemical, Oil & Gas
Products 2017
76
HEAD OFFICE
Stavanger
Phone: +47 90 90 55 00
EUROPE & RUSSIA
Nøtterøy
Phone: +47 90 90 55 00
ASIA PACIFIC
Kuala Lumpur
Phone: +47 90 90 55 00
WORLDWIDE SERVICE ASSISTANCE
Phone: +47 915 09753
E-mail:service.oilgas@autronicafire.no
UNITED KINGDOM
London
Phone: +44 (0) 1753 825 800
Aberdeen
Phone: +44 7495 591 117
THE AMERICAS & WEST AFRICA
Houston
Phone: +1 713-290-8624
SPARE PARTS
Phone: +47 90 90 55 00
E-mail: spareoil.gas@autronicafire.no
MIDDLE EAST/SAUDI ARABIA
Dubai
Phone: +971 0 491 99000
SOUTH KOREA
Busan
Phone: +82 70 71229170
24 HOUR SUPPORT - END USERS ONLY
Phone: +47 48 25 80 00
E-mail: afs.support@autronicafire.no
Contact information
For general sales conditions, go to www.autronicafire.com.
Our mission is clear,
to make the world a safer place to live in. We know how important this task is, and this drives us to constantly develop
smarter solutions.
Our pride and driving force are anchored in saving as many lives as possible, in protecting the environment and in securing property
around us. In many cases, the consequences of a fire are enormous, and we have undertaken to understand how they occur, develop
and can be fought. Our solutions must discover potential hazards in our surroundings as early as possible, without causing false alarms
and uncertainty. This is a delicate balance, and our technology must be equally optimised in large cruise ships, in nuclear power
stations and on oil platforms, as in kindergartens.
A masterly exercise in which we place all our honour.
And in this way, we create the safest and most reliable fire and gas safety products in the world.
Protecting life, environment, and property
www.autronicafire.com
Autronica Fire and Security AS
Division Petrochemical, Oil & Gas | Lagerveien 24, NO-4033 Stavanger, Norway
+47 90 90 55 00 | oil.gas@autronicafire.no | www.autronicafire.com
Org.no.: NO 979 975 503 (MVA/VAT)
116-P-OILANDGAS/SGB, 2017-01-07 | Errors and omissions excepted. Changes may occur without warning